TopPette 12-Channel Pipette 5–50 μL ISO 8655 ATOMFAIR®

$168.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

TopPette 12-channel manual pipette with 5–50 μL range, 0.5 μL increment and ISO 8655-2 calibration reference for PCR/ELISA plates. Order now.

SKU: AF-EI-L-TOPP-E050-12CH
Category: ,
Tags:
Brands:

Description

TopPette 12-channel 5-50 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette 12-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 5-50 µL working range, 0.5 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 5-50 µL with 0.5 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-12CHANNEL-5-50-µL
Product Family TopPette
Channel count 12-channel
Volume range 5-50 µL
Increment 0.5 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The lower half of this pipette is autoclavable where indicated, requiring sterilization cycles that do not exceed manufacturer-recommended temperature and pressure limits. The instrument must be stored in a clean, dry environment within its calibrated temperature range to maintain systematic and random error specifications.

  • Sterilization constraint: Only the lower half of the pipette is autoclavable, and sterilization must follow the indicated protocol to avoid damage to the upper assembly.
  • Calibration constraint: The pipette requires periodic recalibration per ISO 8655-2 to maintain specified systematic and random error at test volumes of 50, 25, and 5 µL.

This procedure covers initial setup, volume adjustment, and tip attachment for the 12-channel pipette before routine liquid handling. Follow these steps to ensure accurate and repeatable microliter transfers in microplate or PCR workflows.

Required Equipment: Compatible pipette tips for 5-50 µL range, Calibration reference standard per ISO 8655-2

  1. Set volume
    Rotate the volume adjustment knob to the desired volume within the 5-50 µL range using the 0.5 µL increment scale.
  2. Attach tips
    Press the pipette firmly onto compatible tips for the 5-50 µL range to ensure a stable seal across all 12 channels.
  3. Verify calibration
    Confirm that the pipette has been calibrated per ISO 8655-2 at the test volumes of 50, 25, and 5 µL before use.
  4. Perform pre-wet cycle
    Aspirate and dispense the selected volume at least three times to equilibrate the tip interior and improve repeatability.

How does the systematic error of the TopPette 12-channel 5-50 µL pipette vary across its volume range?

The systematic error is specified for three test volumes: 50 µL, 25 µL, and 5 µL. The exact values are retained in the technical table and should be reviewed for calibration planning. The pipette is calibrated per ISO 8655-2, and the error values are used to verify accuracy at each test volume.

Which pipette tips are compatible with the TopPette 12-channel 5-50 µL pipette for microplate loading?

The product description does not specify a particular tip brand or model. Users must confirm compatible tips before ordering, as tip fit is critical for repeatability in microplate and PCR plate workflows. The pipette is designed for a 5-50 µL volume range, so tips should be selected accordingly.

What are the sterilization requirements for the TopPette 12-channel 5-50 µL pipette?

Only the lower half of the pipette is autoclavable where indicated; the upper half is not autoclavable. Users should follow the manufacturer's guidelines for sterilization to avoid damage. The pipette is suitable for routine liquid handling where sterilization of the lower half is required.

The TopPette 12-channel 5-50 µL pipette offers a dedicated microliter liquid handling platform with a 0.5 µL increment and autoclavable lower half, suitable for microplate and PCR workflows where traceable ISO 8655-2 calibration data and repeatable parallel transfers are required.

Positive

  • 12-channel high-throughput design: Enables efficient microplate loading, PCR plate preparation, and parallel reagent transfer, reducing handling time in multichannel workflows.
  • Autoclavable lower half for sterility: The lower assembly can be autoclaved where indicated, allowing decontamination between uses in sensitive applications.

Trade-offs

  • Restricted volume range: The 5-50 µL range and 0.5 µL increment limit the pipette to microliter-scale dispensing; not suitable for microliter volumes below 5 µL or above 50 µL.
  • Tip and calibration dependency: Accurate performance requires compatible tips and routine calibration per ISO 8655-2; users must confirm tip fit and calibration schedule before deployment.