TopPette 8-channel 10-100 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
Only the lower half of the pipette is autoclavable; the upper assembly must not be subjected to steam sterilization. Calibration must be performed according to ISO 8655-2 user calibration reference to maintain traceable accuracy.
- Sterilization Constraint: The lower half of the pipette is autoclavable, but the upper half must never be autoclaved.
- Calibration Requirement: Calibration must adhere to the ISO 8655-2 user calibration reference to ensure systematic and random error remain within specified limits.
- Tip Compatibility: Only tips specifically designed for 8-channel pipettes must be used to ensure proper fit, seal, and accuracy.
This manual pipette requires calibration verification and proper tip selection before use. Only the lower half is autoclavable for sterilization between uses.
Required Equipment: Compatible 8-channel pipette tips, Calibration documentation (ISO 8655-2)
- Inspect and verify calibration
Inspect the pipette for cleanliness and damage, and verify that calibration documentation is current and within tolerance. - Attach compatible tips
Select and attach compatible 8-channel tips securely to ensure proper sealing and accurate liquid handling. - Set target volume
Set the desired volume using the 1 µL increment adjustment, confirming the volume indicator is aligned with the intended value. - Perform liquid transfer
Perform liquid transfer by depressing the plunger smoothly to the first stop, immersing tips, and releasing slowly to aspirate.
What is the significance of the systematic error and random error data provided for the TopPette 8-channel pipette?
The systematic error and random error values are listed for test volumes 100, 50, and 10 µL, allowing users to assess accuracy and precision at typical working volumes. This data supports calibration review according to ISO 8655-2 and helps in method setup and routine performance evaluation.
Is the TopPette 8-channel pipette fully autoclavable for sterile applications?
Only the lower half of the pipette is autoclavable where indicated. The upper half should not be autoclaved. This partial sterilization capability is suitable for decontaminating the parts that come into contact with liquid, but the entire pipette cannot be sterilized.
What calibration reference standard does the TopPette 8-channel pipette adhere to?
The pipette is calibrated according to ISO 8655-2 user calibration reference, as indicated in the technical table. This international standard specifies requirements for piston-operated volumetric apparatus, ensuring traceable calibration data for research and quality control laboratories.
The TopPette 8-channel 10-100 µL pipette is a manual multichannel pipette designed for high-throughput microplate and PCR workflows. Its 8-channel configuration and 1 µL increment enable precise parallel liquid handling, but sterilization is limited to the lower half and calibration data must be referenced from separate technical tables.
Positive
- 8-channel parallel liquid handling: 8-channel configuration supports microplate loading, PCR plate preparation, ELISA workflows, and repeated parallel reagent transfer, increasing throughput for routine lab tasks.
- Partial autoclavable sterilization: Lower half is autoclavable where indicated, reducing contamination risk in critical applications without requiring full disassembly.
Trade-offs
- Limited sterilization coverage: Only the lower half is autoclavable; the upper assembly requires alternative decontamination methods, which may complicate complete sterilization workflows.
- Calibration data not explicitly listed: Systematic and random error values are referenced to a technical table but not provided in the product description, requiring users to consult separate documentation for calibration verification.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.