Description
MicroPette Plus 8-channel 10-100 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette requires periodic calibration per ISO 8655-2 and supports full autoclaving for sterilization. Tip compatibility must be verified to maintain volumetric accuracy, and the instrument is designed for repeated parallel liquid transfers in microplate and PCR workflows.
- Sterilization Requirement: The pipette can be fully autoclaved at 121°C for sterilization, but care must be taken to allow complete drying before reuse to prevent moisture-related damage.
- Calibration Requirement: Calibration must be performed according to ISO 8655-2 using the specified test volumes to ensure systematic and random errors remain within acceptable limits.
- Tip Compatibility: Only compatible tips that fit the 8-channel nozzle array and form a proper seal should be used to avoid leakage, tip ejection failure, and volume inaccuracy.
- Volume Range Constraint: The pipette is designed for a 10-100 µL working range with 1 µL increments; operating outside this range may cause mechanical stress or calibration drift.
How does the systematic error of the MicroPette Plus 8-channel 10-100 µL pipette vary across different test volumes, and does it comply with ISO 8655-2?
The systematic error is specified for each test volume (100 µL, 50 µL, 10 µL) in the technical specifications. The pipette is calibrated according to ISO 8655-2, which provides a user calibration reference. Exact error values are retained in the product's technical table and should be reviewed for the specific test volumes relevant to the application.
Is the MicroPette Plus 8-channel pipette compatible with standard 96-well microplates and PCR plates for high-throughput workflows?
Yes, the 8-channel configuration is specifically designed for microplate loading, PCR plate preparation, and ELISA workflows. The 10-100 µL volume range and 1 µL increment support repeated parallel reagent transfer in these formats. However, users should confirm compatible tips and calibration requirements before ordering.
Can the MicroPette Plus 8-channel pipette be fully autoclaved without affecting its calibration, and what post-sterilization steps are recommended?
The pipette is fully autoclavable for sterilization. Because autoclaving can affect mechanical components, it is recommended to verify calibration after sterilization using the ISO 8655-2 user calibration reference provided in the technical table. Contact Atomfair technical support for method-specific calibration planning.
The MicroPette Plus 8-channel 10-100 µL pipette is a fully autoclavable manual pipette with an 8-channel configuration for high-throughput microplate loading, PCR preparation, and ELISA workflows, featuring systematic and random error specifications per test volume for calibration to ISO 8655-2. Its 10-100 µL range and 1 µL increment constrain it to volumes above 10 µL, and tip compatibility must be verified prior to ordering.
Positive
- 8-channel high-throughput design: The 8-channel configuration enables efficient microplate loading, PCR plate preparation, ELISA workflows, and repeated parallel reagent transfer, increasing throughput in research and quality-control labs.
- Fully autoclavable sterilization: The pipette can be fully autoclaved, allowing safe decontamination and reuse in sterile or biohazard laboratory environments.
Trade-offs
- Requires compatible tip verification: The pipette requires confirmation of compatible tips before ordering to ensure proper fit and accuracy, as tip compatibility is not universal.
- Volume range limited to 10-100 µL: The working range of 10-100 µL with a 1 µL increment restricts use to microliter volumes above 10 µL, excluding sub-10 µL pipetting applications.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).