Mi-Pette 8-channel 5-50 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette 8-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-8CHANNEL-5-50-µL
Product Family Mi-Pette
Channel count 8-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error At 50 µL: ±1 µL (±2.0%); at 25 µL: ±1 µL (±4.0%); at 5 µL: ±1 µL (±20%)
Random error At 50 µL: ±0.4 µL (±0.8%); at 25 µL: ±0.4 µL (±1.6%); at 5 µL: ±0.4 µL (±8.0%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires strict adherence to calibration, sterilization, and tip compatibility constraints to maintain accuracy and repeatability. Failure to observe these constraints may lead to measurement errors or damage to the instrument.

  • Calibration Requirement: The pipette must be calibrated according to ISO 8655-2 at the specified test volumes (50, 25, 5 µL) to ensure systematic and random error remain within listed tolerances.
  • Sterilization Constraint: High-temperature sterilization is only permissible when explicitly indicated by the source family; otherwise, alternative sterilization methods must be used.
  • Tip Compatibility: Only compatible pipette tips that provide a secure and stable seal should be used to avoid inaccurate volume delivery and tip ejection failure.

How does the accuracy of the Mi-Pette 8-channel 5-50 µL pipette compare between low and high volume settings?

At the maximum test volume of 50 µL, systematic error is ±1.0 µL (±2.0%) and random error is ±0.4 µL (±0.8%). At the minimum test volume of 5 µL, systematic error remains ±1.0 µL but rises to ±20% relative, and random error is ±0.4 µL (±8.0%). Therefore, the pipette delivers significantly higher relative accuracy at the upper end of its range.

What calibration standard does the Mi-Pette 8-channel 5-50 µL pipette follow, and is user calibration supported?

The pipette is calibrated per ISO 8655-2, and the technical specifications include a user calibration reference. Systematic and random error values are provided for 50 µL, 25 µL, and 5 µL test volumes to support in-house calibration verification and method setup.

Can the Mi-Pette 8-channel 5-50 µL pipette be sterilized by autoclaving, and what precautions are needed?

Yes, the pipette supports high-temperature sterilization where indicated by the source family. It is described as fully autoclavable, but users should confirm compatible tips, sterilization requirements, and laboratory workflow before ordering to ensure proper handling and decontamination.

The Mi-Pette 8-channel 5-50 µL manual pipette enables efficient parallel liquid handling for microplate and PCR workflows with full autoclavability, but users must account for significantly degraded accuracy (±20% systematic error) and precision (±8% random error) when operating at the 5 µL end of its volume range.

Positive

  • 8-channel parallel pipetting for high-throughput workflows: The 8-channel configuration directly supports microplate loading, PCR plate preparation, ELISA workflows, and repeated parallel reagent transfer, reducing processing time in multi-sample assays.
  • Fully autoclavable for aseptic handling: The pipette supports high-temperature sterilization, enabling decontamination and reuse in sterile laboratory environments without disassembly.

Trade-offs

  • Accuracy degrades at lower volume range: Systematic error at 5 µL is ±1 µL (±20%), compared to ±1 µL (±2.0%) at 50 µL, making low-volume transfers less accurate and requiring careful calibration and method validation.
  • Precision degrades at lower volume range: Random error at 5 µL is ±0.4 µL (±8.0%), versus ±0.4 µL (±0.8%) at 50 µL, reducing repeatability for sub-10 µL pipetting steps critical in sensitive assays.