Description
HiPette 12-channel 5-50 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires careful calibration and tip selection to achieve accurate liquid handling. It must be used within its volume range and calibrated at specified test volumes.
- Tip Compatibility: Use only 12-channel pipette tips rated for 5-50 µL to ensure proper fit and accuracy.
- Calibration Requirements: Calibrate the pipette at test volumes of 50, 25, and 5 µL following ISO 8655-2 to maintain specified error limits.
- Volume Range: Operate the pipette only within the 5-50 µL volume range to avoid mechanical stress and ensure dispensing precision.
How does the systematic error of the HiPette 12-channel 5-50 µL pipette vary across the three test volumes (50, 25, 5 µL), and what impact does this have on low-volume pipetting accuracy?
The systematic error values are provided for each test volume (50, 25, 5 µL) in the technical table; users should consult these values to assess accuracy at their working volume. At the lowest test volume (5 µL), the relative error contribution is larger than at 50 µL, so the pipette is best suited for mid- to high-volume applications within the 5–50 µL range. The 0.05 µL increment allows fine adjustment, but performance at low microliter volumes depends on the specific systematic error listed in the supplied table.
What type of tips are compatible with the HiPette 12-channel 5-50 µL pipette, and does the fully autoclavable design affect tip compatibility or require special handling after sterilization?
The product description states that users must confirm compatible tips before ordering; no specific tip brand or model is listed. The pipette is fully autoclavable, meaning the entire unit can be sterilized without disassembly, but tips must be removed before autoclaving. After sterilization, the pipette should be allowed to cool and dry completely before use with fresh tips to maintain proper fit and accuracy.
What calibration standard does the HiPette 12-channel 5-50 µL pipette comply with, and how frequently should calibration be performed to maintain ISO 8655-2 compliance in a regulated laboratory?
The pipette complies with ISO 8655-2, which provides a user calibration reference. The product description does not specify a calibration interval, but typical laboratory practice requires calibration every 3–12 months depending on usage frequency and regulatory requirements. The technical table includes systematic and random error values for each test volume (50, 25, 5 µL) to facilitate routine calibration checks against the ISO 8655-2 standard.
The HiPette 12-channel 5-50 µL pipette offers a parallel liquid handling platform with full autoclavability and calibration traceability to ISO 8655-2, suitable for high-throughput microplate and PCR workflows. The user must verify tip compatibility and manage periodic calibration to maintain specified accuracy.
Positive
- 12-channel parallel pipetting for high-throughput workflows: The 12-channel configuration enables simultaneous parallel liquid transfer, significantly speeding up microplate loading, PCR plate preparation, and ELISA workflows compared to single-channel alternatives.
- Fully autoclavable for sterilization and decontamination: The entire pipette withstands autoclaving, allowing complete sterilization between uses to prevent cross-contamination in sensitive biological and clinical assays.
Trade-offs
- Tip compatibility must be verified prior to use: The pipette requires confirmation of compatible tip models; improper tip fit can compromise accuracy, precision, and seal integrity, necessitating pre-purchase tip validation.
- User must manage calibration planning and execution: The calibration reference to ISO 8655-2 indicates that the laboratory is responsible for scheduling and performing periodic recalibration to maintain specified systematic and random error limits.