HiPette-LTS 16-Channel Manual Pipette 5-100 μL ATOMFAIR®

$558.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable 16-channel manual pipette with 5-100 μL range, 0.1 μL increments and ISO 8655-2 calibration reference for microplate work. Order now.

SKU: AF-EI-L-HPLT-E100-16CH
Category: ,
Tags:
Brands:

Description

HiPette-LTS 16-channel 5-100 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS 16-channel 5-100 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-100 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 16-channel format, 5-100 µL working range, 0.1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 16-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 5-100 µL with 0.1 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-16CHANNEL-5-100-µL
Product Family HiPette-LTS
Channel count 16-channel
Volume range 5-100 µL
Increment 0.1 µL
Test volume(s) 100 / 50 / 10 µL
Systematic error At 100 µL: ±1.0 µL (±1.0%); at 50 µL: ±0.6 µL (±1.2%); at 10 µL: ±0.3 µL (±3.0%)
Random error At 100 µL: ±0.6 µL (±0.6%); at 50 µL: ±0.4 µL (±0.8%); at 10 µL: ±0.2 µL (±2.0%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy and precision across its volume range. Full autoclaving at 121°C is permitted for sterilization, but repeated cycles may affect calibration stability.

  • Calibration Requirement: Systematic and random error tolerances are defined at 100 µL, 50 µL, and 10 µL test volumes, requiring user verification against ISO 8655-2.
  • Sterilization Constraint: Fully autoclavable construction allows steam sterilization, but thermal cycling may necessitate recalibration after multiple autoclave runs.

This manual pipette is designed for parallel liquid transfer in microplate and PCR workflows. Proper tip attachment, volume setting, and dispensing technique are critical for accuracy.

Required Equipment: Compatible pipette tips (5-100 µL range), Calibration reference standard per ISO 8655-2

  1. Attach tips
    Press the pipette firmly onto compatible tips to ensure a stable, airtight seal across all 16 channels.
  2. Set volume
    Rotate the volume adjustment knob to the desired volume within the 5-100 µL range using the 0.1 µL increment.
  3. Aspirate liquid
    Depress the plunger to the first stop, immerse tips into the liquid, and release slowly to draw sample.
  4. Dispense liquid
    Press the plunger to the first stop, then to the second stop to expel all liquid from the tips.
  5. Eject tips
    Press the tip ejector button to discard used tips into an appropriate waste container.
  6. Autoclave for sterilization
    Disassemble the pipette if required and autoclave at 121°C for 20 minutes, then allow to cool before reassembly.

How does the systematic error and random error vary across the 10 µL, 50 µL, and 100 µL test volumes for the HiPette-LTS 16-channel pipette?

At 100 µL systematic error is ±1.0 µL (1.0%) and random error ±0.6 µL (0.6%); at 50 µL systematic error ±0.6 µL (1.2%) and random error ±0.4 µL (0.8%); at 10 µL systematic error ±0.3 µL (3.0%) and random error ±0.2 µL (2.0%). This shows that accuracy and precision decrease at lower volumes.

What calibration standard does the HiPette-LTS 16-channel pipette reference for user calibration?

The pipette's technical table indicates a calibration reference of ISO 8655-2 user calibration reference. This standard is used for the systematic and random error values listed at test volumes.

Can the HiPette-LTS 16-channel pipette be fully sterilized by autoclaving?

Yes, the pipette is fully autoclavable, allowing complete sterilization of the instrument. However, the product description does not specify specific autoclave cycle parameters; users should follow standard laboratory protocols or consult the manufacturer for detailed guidelines.

This HiPette-LTS 16-channel pipette offers a 5-100 µL range with 0.1 µL increment and full autoclavability, but users must account for increased relative error at low volumes and ensure tip and calibration compatibility.

Positive

  • Fully autoclavable for sterilization: Entire pipette can be autoclaved without disassembly, enabling reliable decontamination between workflows.
  • 16-channel format boosts throughput: Supports parallel liquid transfer for microplate loading, PCR preparation, and ELISA workflows, reducing processing time.

Trade-offs

  • Higher relative error at low volumes: Systematic error at 10 µL is ±3.0% (±0.3 µL), which may limit accuracy for sub-10 µL applications or protocols requiring tighter precision.
  • Tip and calibration dependency: Optimal performance requires compatible tips and regular calibration verification per ISO 8655-2; workflow planning must account for these prerequisites.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).