16-Channel Manual Pipette 1-20 μL HiPette-LTS ATOMFAIR®

$558.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette-LTS 16-channel manual pipette with 1-20 μL range, 0.01 μL increment and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HPLT-C020-16CH
Category: ,
Brands:

Description

HiPette-LTS 16-channel 1-20 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS 16-channel 1-20 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 1-20 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 16-channel format, 1-20 µL working range, 0.01 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 16-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 1-20 µL with 0.01 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-16CHANNEL-1-20-µL
Product Family HiPette-LTS
Channel count 16-channel
Volume range 1-20 µL
Increment 0.01 µL
Test volume(s) 20 / 10 / 2 µL
Systematic error At 20 µL: ±0.4 µL (±2.0%); at 10 µL: ±0.4 µL (±4.0%); at 2 µL: ±0.16 µL (±8.0%)
Random error At 20 µL: ±0.2 µL (±1.0%); at 10 µL: ±0.2 µL (±2.0%); at 2 µL: ±0.1 µL (±5.0%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The HiPette-LTS 16-channel pipette requires regular calibration per ISO 8655-2 to maintain specified accuracy and precision across test volumes of 20, 10, and 2 µL. Sterilization is achieved via full autoclaving, which necessitates compatible tip selection and may require recalibration after each cycle.

  • Calibration Schedule: The pipette must be calibrated at regular intervals per ISO 8655-2 using the specified test volumes of 20, 10, and 2 µL to maintain volumetric accuracy.
  • Tip Compatibility: Only tips designed for 16-channel pipettes in the 1-20 µL range should be used to ensure proper sealing and reproducible liquid transfer.
  • Sterilization Protocol: The pipette is fully autoclavable; calibration should be verified after autoclaving to confirm performance remains within specified error limits.

How does the systematic and random error of the HiPette-LTS 16-channel pipette vary across its volume range, and what does this mean for assay precision at sub-10 µL volumes?

The pipette's systematic error increases from ±2.0% at 20 µL to ±8.0% at 2 µL, and random error increases from ±1.0% at 20 µL to ±5.0% at 2 µL. This means that for low-volume assays near 2 µL, users must account for significantly higher relative error, which may impact replicate reproducibility and require careful calibration verification.

What tip compatibility and plate format considerations are required for the 16-channel 1-20 µL pipette?

The 16-channel configuration is designed for microplate loading, PCR plate preparation, and ELISA workflows, typically compatible with 96-well plates. The pipette requires compatible tips within the 1-20 µL range; the description advises confirming compatible tips before ordering to ensure proper sealing and accuracy.

What are the sterilization and calibration requirements for maintaining the HiPette-LTS 16-channel pipette in a routine lab?

The pipette is fully autoclavable, but the description does not specify exact autoclave parameters; users should follow standard lab sterilization protocols. Calibration is referenced to ISO 8655-2, and the technical table provides systematic and random error values at test volumes for user calibration verification. Routine calibration checks are recommended to maintain accuracy, especially after autoclaving.

The HiPette-LTS 16-channel 1-20 µL pipette offers fully autoclavable construction for aseptic liquid handling, with systematic and random error specifications that are acceptable for routine microplate and PCR workflows but show reduced accuracy at the lower end of the range near 2 µL.

Positive

  • Fully autoclavable sterilization: The pipette is fully autoclavable, enabling routine sterilization for aseptic liquid handling in microbiology, cell culture, and molecular biology workflows without disassembly.
  • 16-channel parallel processing: The 16-channel configuration supports high-throughput microplate loading, PCR plate preparation, and ELISA workflows, reducing manual pipetting steps and improving repeatability in parallel reagent transfer.

Trade-offs

  • Reduced accuracy at low volumes: At 2 µL, systematic error is ±8.0% and random error ±5.0%, significantly higher than at 20 µL, limiting precision for very low-volume applications without careful calibration.
  • Requires tip and calibration planning: Performance depends on selecting compatible tips and regular calibration per ISO 8655-2; users must plan for tip compatibility and calibration scheduling to maintain specified tolerances.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).