Description

HiPette-LTS 12-channel 30-300 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS 12-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 30-300 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 30-300 µL with 0.2 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-12CHANNEL-30-300-µL
Product Family HiPette-LTS
Channel count 12-channel
Volume range 30-300 µL
Increment 0.2 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The HiPette-LTS 12-channel pipette requires adherence to sterilization, calibration, and tip compatibility constraints to maintain performance and accuracy. This device must be used within its specified volume range and error tolerances per ISO 8655-2.

  • Sterilization Requirement: The pipette is fully autoclavable and must be sterilized after each use when handling biohazardous materials.
  • Calibration Standard: Calibration must be performed according to ISO 8655-2 using the three test volumes (300, 150, 30 µL) to verify systematic and random error against published limits.
  • Volume Range Limitation: Only volumes between 30 and 300 µL in 0.2 µL increments should be aspirated to avoid mechanical damage and maintain accuracy.
  • Tip Compatibility: Only manufacturer-recommended tips must be used to ensure a proper seal and prevent leakage or volume inaccuracy.
  • Error Verification: Systematic and random error must be verified at each test volume using a calibrated analytical balance; deviation from specified limits indicates the need for recalibration or service.

How does the systematic error of the HiPette-LTS 12-channel pipette vary across the 30–300 µL range?

Systematic error is specified per test volume in the product's technical table, with values retained for the three test volumes: 300 µL, 150 µL, and 30 µL. The pipette is calibrated according to ISO 8655-2 user calibration reference, ensuring traceable accuracy at each point. For precise numerical error values at each test volume, consult the technical table provided with the instrument.

Can the HiPette-LTS 12-channel pipette be used for PCR plate preparation and ELISA workflows?

Yes, the 12-channel 30–300 µL pipette is specifically designed for microplate loading, PCR plate preparation, ELISA workflows, and repeated parallel reagent transfer. Its 12-channel format and 0.2 µL increment support efficient, reproducible liquid handling in these applications. Users should confirm tip compatibility with the manufacturer before use.

What are the sterilization requirements for the HiPette-LTS 12-channel pipette?

The HiPette-LTS 12-channel pipette is fully autoclavable, allowing complete sterilization of the entire instrument for laboratory protocols requiring sterile conditions. No additional sterilization accessories are needed; the pipette can be placed directly in an autoclave. Users should confirm sterilization cycles compatible with the pipette's materials by consulting the product manual.

The HiPette-LTS 12-channel 30-300 µL pipette is a fully autoclavable manual pipette designed for parallel liquid handling in microplate, PCR, and ELISA applications. Its technical performance is traceable to ISO 8655-2, though error specifications require consultation of the calibration table, and tip compatibility must be verified independently.

Positive

  • Fully autoclavable for aseptic protocols: Entire pipette can be autoclaved, enabling sterile operation in microbiological and molecular biology workflows without disassembly.
  • 12-channel parallel dispensing for throughput: 12-channel design reduces manual pipetting steps in microplate, PCR, and ELISA workflows, improving reproducibility and speed.

Trade-offs

  • No explicit tip compatibility listed: The product description advises confirming compatible tips before ordering, indicating that tip fit may not be universal and requires pre-validation.
  • Calibration error values not directly stated: Systematic and random errors are referenced to an internal technical table per ISO 8655-2, but absolute error values are not provided in the listing, necessitating reference to calibration documentation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).