HiPette-LTS 8-channel 0.5-10 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette must be calibrated per ISO 8655-2 to maintain specified accuracy across test volumes. The device is fully autoclavable for sterilization but requires confirmation of tip compatibility before each use.
- Calibration Requirement: Systematic and random error values are defined for test volumes of 10, 5, and 1 µL and must be verified against ISO 8655-2 reference during routine calibration.
- Sterilization Constraint: The pipette can be fully autoclaved after disassembly, but the sterilization cycle parameters and tip compatibility must be confirmed to avoid damage or leakage.
What are the systematic and random error specifications for the HiPette-LTS 8-channel pipette at the 1 µL test volume?
The source does not provide numerical values for systematic and random error in this description, but states that they are retained by test volume and listed in the technical table. The pipette is calibrated per ISO 8655-2, and the test volumes are 10, 5, and 1 µL. For exact error values, consult the product's full technical datasheet.
What sterilization method is recommended for the HiPette-LTS 8-channel pipette, and can it be autoclaved with the tips attached?
The pipette is described as fully autoclavable, indicating it can be sterilized by autoclave. The source does not specify whether tips should be attached during autoclaving, so it is recommended to confirm sterilization requirements and tip compatibility with the supplier before use.
What infrastructure is required to maintain calibration compliance for the HiPette-LTS 8-channel pipette in a laboratory?
The pipette is designed for user calibration per ISO 8655-2, and the technical table includes systematic and random error values for each test volume. For calibration planning and to maintain compliance, the source recommends contacting Atomfair technical sales for support.
The HiPette-LTS 8-channel 0.5-10 µL pipette offers fully autoclavable construction and fine 0.01 µL increments for precise low-volume parallel liquid handling, but requires careful tip compatibility verification and routine calibration per ISO 8655-2 to maintain specified accuracy.
Positive
- Fully autoclavable sterilization: The entire pipette can be autoclaved without disassembly, enabling thorough decontamination between workflows and reducing contamination risk in sensitive applications.
- 8-channel parallel dispensing: The 8-channel format supports simultaneous reagent transfer for microplate loading, PCR preparation, and ELISA workflows, improving throughput and repeatability in parallel liquid handling.
Trade-offs
- Tip compatibility dependency: Proper seal and accuracy depend on using confirmed compatible tips; tip selection must be verified before use to avoid performance degradation.
- Routine calibration required: To maintain specified systematic and random error limits, periodic calibration per ISO 8655-2 is necessary, requiring calibration planning and documentation.