TopPette Single-Channel 100-1000 µL Pipette ATOMFAIR®

$19.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

TopPette single-channel manual pipette covers 100-1000 µL with 1 µL increments, ISO 8655-2 calibration reference, and lower-half autoclaving. Order now.

SKU: AF-EI-L-TOPP-M1K0-SC00
Category: ,
Tags:
Brands:

Description

TopPette Single-channel 100-1000 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette Single-channel 100-1000 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 100-1000 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 100-1000 µL working range, 1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 100-1000 µL with 1 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-100-1000-µL
Product Family TopPette
Channel count Single-channel
Volume range 100-1000 µL
Increment 1 µL
Test volume(s) 1000 / 500 / 100 µL
Systematic error At 1000 µL: ±6.00 µL (±0.6%); at 500 µL: ±5.00 µL (±1.0%); at 100 µL: ±3.00 µL (±3.0%)
Random error At 1000 µL: ±2.00 µL (±0.2%); at 500 µL: ±1.00 µL (±0.2%); at 100 µL: ±0.60 µL (±0.6%)
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic calibration according to ISO 8655-2 to maintain accuracy. Only the lower half of the pipette is autoclavable, and compatible tips must be used to ensure proper volume delivery.

  • Calibration Requirement: Calibration must be performed periodically per ISO 8655-2 using the test volumes listed in the technical table to maintain systematic and random error within specified limits.
  • Sterilization Limitation: Only the lower half of the pipette can be autoclaved; the upper half must not be subjected to autoclaving to prevent damage.
  • Tip Compatibility: Compatible tips must be selected to ensure stable tip fit and accurate volume delivery across the 100-1000 µL range.

How does the systematic error of the TopPette 100-1000 µL pipette change at lower volumes, and what is the resulting accuracy at 100 µL?

At 1000 µL, systematic error is ±0.6% (±6.00 µL); at 500 µL, ±1.0% (±5.00 µL); at 100 µL, ±3.0% (±3.00 µL). This trade-off means accuracy decreases significantly at the lower end of the range, which is typical for manual pipettes. The random error at 100 µL is ±0.6% (±0.60 µL).

Which tip types are compatible with the TopPette 100-1000 µL pipette, and does it require calibration according to ISO 8655-2?

The pipette is a single-channel adjustable model with a 100-1000 µL range and 1 µL increment. The description indicates that users should select compatible tips based on the volume range and that calibration is performed according to ISO 8655-2, as listed in the technical table. Specific tip brand or type is not specified, so users must confirm compatibility before ordering.

What are the sterilization requirements for the TopPette 100-1000 µL pipette, and is the entire unit autoclavable?

The pipette is described as a fully autoclavable manual pipette, but the technical specifications state that only the lower half is autoclavable where indicated. Therefore, users should confirm which parts are autoclavable and follow the manufacturer's guidelines to avoid damage. The pipette is suitable for routine liquid transfer and assay setup, and sterilization should be performed according to lab protocols.

The TopPette 100-1000 µL single-channel manual pipette provides a fully autoclavable lower half and ISO 8655-2 calibration traceability, but its sterilization is restricted to the lower assembly and systematic error at 100 µL reaches ±3.0%, a notable accuracy constraint at the low end of the range.

Positive

  • Autoclavable lower half: The lower assembly of the pipette can be autoclaved, enabling effective decontamination between uses without requiring full pipette sterilization.
  • ISO 8655-2 calibration traceability: Systematic and random error values are listed per test volume with calibration reference to ISO 8655-2, supporting routine performance verification and method validation.

Trade-offs

  • Lower half autoclavable only: Only the lower half of the pipette is autoclavable; the upper handle requires alternative disinfection methods, which may complicate complete sterilization protocols.
  • High systematic error at 100 µL: At the 100 µL test volume, systematic error is ±3.0% (±3.00 µL), significantly higher than at larger volumes, which reduces accuracy for low-volume transfers.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).