TopPette 10-100 µL Single-Channel Pipette ATOMFAIR®

$19.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Manual single-channel pipette for 10-100 µL transfer with 0.1 µL increment, ISO 8655-2 calibration reference and lower-half autoclavable design. Order now.

SKU: AF-EI-L-TOPP-F100-SC00
Category: ,
Tags:
Brands:

Description

TopPette Single-channel 10-100 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette Single-channel 10-100 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 10-100 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 10-100 µL working range, 0.1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 10-100 µL with 0.1 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-10-100-µL
Product Family TopPette
Channel count Single-channel
Volume range 10-100 µL
Increment 0.1 µL
Test volume(s) 100 / 50 / 10 µL
Systematic error At 100 µL: ±0.80 µL (±0.8%); at 50 µL: ±0.50 µL (±1.0%); at 10 µL: ±0.30 µL (±3.0%)
Random error At 100 µL: ±0.20 µL (±0.2%); at 50 µL: ±0.15 µL (±0.3%); at 10 µL: ±0.10 µL (±1.0%)
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette must be calibrated per ISO 8655-2 at specified test volumes to maintain accuracy. Only the lower half of the pipette is autoclavable, limiting sterilization options.

  • Calibration accuracy specification: Systematic error and random error tolerances are defined at each test volume according to ISO 8655-2 user calibration reference.
  • Sterilization limitation: Only the lower half of the pipette is autoclavable; the upper assembly should not be exposed to steam sterilization.

What is the accuracy and precision trade-off when using the TopPette 10-100 µL pipette at low volumes near 10 µL compared to near full scale 100 µL?

The pipette's systematic error increases from ±0.8% at 100 µL to ±3.0% at 10 µL, while random error increases from ±0.2% to ±1.0%. This means accuracy and precision degrade significantly at the lower end of the range, which is critical for methods requiring high fidelity at small volumes.

Can the TopPette 10-100 µL pipette be fully autoclaved for sterilization in aseptic workflows?

No, only the lower half of the pipette is autoclavable where indicated, not the entire instrument. This limitation must be considered when planning sterilization protocols for contamination-sensitive applications such as PCR or cell culture work.

What calibration standard does the TopPette 10-100 µL pipette reference and how does it support method validation?

The pipette references ISO 8655-2 for user calibration, which is the international standard for piston-operated volumetric apparatus. This provides a traceable basis for in-lab calibration verification and routine performance review, directly supporting method validation in regulated environments.

This manual single-channel pipette (10–100 µL, 0.1 µL increment) delivers ISO 8655-2 traceable performance with systematic errors ranging from ±0.8% at full volume to ±3.0% at 10 µL; partial autoclavability of the lower half supports routine decontamination but requires separate sterilization of the upper assembly.

Positive

  • High accuracy at upper range: At 100 µL, systematic error is ±0.80 µL (±0.8%) and random error ±0.20 µL (±0.2%), providing reliable performance for routine quantitative transfer and assay setup.
  • Partial autoclavability for decontamination: The lower half is autoclavable, allowing heat-based sterilization of tip-contact components without requiring full pipette disassembly.

Trade-offs

  • Elevated error at low end of range: At 10 µL, systematic error rises to ±0.30 µL (±3.0%) and random error to ±0.10 µL (±1.0%); users requiring high precision near the lower limit should verify calibration with their specific workflow.
  • Upper assembly not autoclavable: Only the lower half is autoclavable; the upper body and handle require alternative decontamination methods (e.g., chemical wipes), adding protocol constraints for aseptic applications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).