MicroPette Plus Autoclavable Pipette 1000-10000 µL ATOMFAIR®

$34.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable MicroPette Plus single-channel pipette, 1000-10000 µL with 100 µL increment and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-MCPL-Q10K-SC00
Category: ,
Tags:
Brands:

Description

MicroPette Plus Single-channel 1000-10000 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

MicroPette Plus Single-channel 1000-10000 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 1000-10000 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 1000-10000 µL working range, 100 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 1000-10000 µL with 100 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MICROPETTE-PLUS-1000-10000-µL
Product Family MicroPette Plus
Channel count Single-channel
Volume range 1000-10000 µL
Increment 100 µL
Test volume(s) 10000 / 5000 / 1000 µL
Systematic error At 10000 µL: ±60.00 µL (±0.60%); at 5000 µL: ±60.00 µL (±1.20%); at 1000 µL: ±30.00 µL (±3.00%)
Random error At 10000 µL: ±20.00 µL (±0.20%); at 5000 µL: ±15.00 µL (±0.30%); at 1000 µL: ±6.00 µL (±0.60%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires calibration per ISO 8655-2 at three test volumes to maintain systematic and random error within published limits. Sterilization must be performed by full autoclaving, and only compatible tips should be used to ensure accuracy and proper tip fit.

  • Calibration requirement: Calibrate the pipette at 10000 µL, 5000 µL, and 1000 µL using the user calibration reference per ISO 8655-2.
  • Sterilization procedure: Sterilize the fully disassembled pipette by autoclaving according to the manufacturer's instructions.
  • Tip compatibility: Select only tips certified for the 1000-10000 µL volume range to ensure correct sealing and volumetric accuracy.
  • Volume adjustment: Set the desired volume in 100 µL increments within the 1000-10000 µL range using the adjustment knob.

How does the measurement accuracy of the MicroPette Plus 1000-10000 µL pipette change as the target volume decreases from 10000 µL to 1000 µL?

At 10000 µL, systematic error is ±60 µL (±0.60%) and random error is ±20 µL (±0.20%). At 1000 µL, systematic error is ±30 µL (±3.00%) and random error is ±6 µL (±0.60%). The absolute error decreases but the relative error increases significantly, making the pipette less accurate at the lower end of the range.

What calibration and tip compatibility requirements must be met when using the MicroPette Plus 1000-10000 µL pipette in a regulated laboratory?

The pipette is calibrated per ISO 8655-2 with a user calibration reference indicated in the technical table. Users must confirm compatible tips for the 1000-10000 µL range before ordering. The single-channel format is suitable for PCR, qPCR, and serial dilution, but tip fit and calibration status must be verified for each application.

Can the MicroPette Plus 1000-10000 µL pipette be fully sterilized by autoclaving, and are there any specific cycle parameters required?

The pipette is specified as fully autoclavable, enabling sterilization for aseptic workflows. However, the product description does not provide specific autoclave temperature, pressure, or cycle duration; users should follow standard manual pipette autoclaving guidelines and confirm compatibility with their laboratory's sterilization equipment.

The MicroPette Plus single-channel manual pipette offers a 1000-10000 µL range with ISO 8655-2 calibration and full autoclavability, but users must account for the 100 µL increment and higher relative error at the minimum volume.

Positive

  • Fully autoclavable for sterilization: The pipette can be sterilized by autoclaving without disassembly, ensuring aseptic handling for sensitive biological and molecular workflows.
  • ISO 8655-2 calibration traceability: Systematic and random error values are listed per test volume with calibration reference to ISO 8655-2, supporting reproducible liquid handling and audit compliance.

Trade-offs

  • Coarse 100 µL volume increment: Volume adjustment is limited to 100 µL steps, preventing precise setting of intermediate volumes and restricting workflow flexibility for non-standard target volumes.
  • Elevated relative error at low range: At 1000 µL the systematic error reaches ±3.00%, significantly higher than at mid and full scale, which may compromise accuracy in low-volume quantitative assays.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).