MicroPette Plus 100-1000 μL Autoclavable Pipette ATOMFAIR®

$34.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable MicroPette Plus single-channel pipette, 100-1000 μL range with 1 μL increments and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-MCPL-M1K0-SC00
Category: ,
Tags:
Brands:

Description

MicroPette Plus Single-channel 100-1000 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

MicroPette Plus Single-channel 100-1000 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 100-1000 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 100-1000 µL working range, 1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 100-1000 µL with 1 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MICROPETTE-PLUS-100-1000-µL
Product Family MicroPette Plus
Channel count Single-channel
Volume range 100-1000 µL
Increment 1 µL
Test volume(s) 1000 / 500 / 100 µL
Systematic error At 1000 µL: ±6.00 µL (±0.6%); at 500 µL: ±5.00 µL (±1.0%); at 100 µL: ±3.00 µL (±3.0%)
Random error At 1000 µL: ±2.00 µL (±0.2%); at 500 µL: ±1.00 µL (±0.2%); at 100 µL: ±0.60 µL (±0.6%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires periodic calibration verification according to ISO 8655-2 to maintain specified accuracy. Autoclaving is the recommended sterilization method, requiring compatible cycles to preserve component integrity.

  • Calibration requirement: Calibration must be verified using gravimetric methods at the test volumes (1000, 500, 100 µL) per ISO 8655-2 to ensure systematic and random errors remain within specifications.
  • Sterilization procedure: Autoclaving is permissible for sterilization, but temperature and duration should follow manufacturer guidelines to prevent damage to the piston and seal.
  • Tip compatibility: Only tips designed for the 100-1000 µL range and with proper fit for MicroPette Plus should be used to maintain volume accuracy and seal integrity.

How does the systematic error of the MicroPette Plus 100-1000 µL pipette change across different test volumes?

The systematic error increases at lower volumes. At 1000 µL it is ±6.00 µL (±0.6%), at 500 µL it is ±5.00 µL (±1.0%), and at 100 µL it is ±3.00 µL (±3.0%). This means relative accuracy degrades significantly when pipetting near the lower end of the range.

Can the MicroPette Plus 100-1000 µL pipette be used for PCR setup and what tip compatibility should be verified?

Yes, the pipette is suitable for PCR and qPCR setup. However, the product description advises confirming compatible tips before ordering, as tip fit is critical for accuracy. Standard 100-1000 µL tips are expected, but users should verify with the supplier to ensure proper sealing and performance.

What sterilization method is recommended for the MicroPette Plus 100-1000 µL pipette?

The pipette is fully autoclavable, meaning it can be sterilized using standard autoclave cycles. The product description does not specify exact parameters, but typical autoclave conditions (e.g., 121°C, 15 psi) are applicable. Ensure the pipette is prepared per the manufacturer's guidelines for sterilization.

The MicroPette Plus Single-channel 100-1000 µL pipette offers full autoclavability and good precision at higher volumes, but exhibits higher systematic error at the lower end of its range, which is typical for manual air-displacement pipettes in this class.

Positive

  • Fully autoclavable for sterility: The entire pipette can be autoclaved at 121°C, making it suitable for aseptic techniques and preventing cross-contamination between samples.
  • Low random error at high volume: At 1000 µL, the random error is ±0.2%, ensuring high repeatability for routine liquid transfers.

Trade-offs

  • Higher systematic error at low volume: At 100 µL, the systematic error is ±3.0 µL (±3.0%), which may limit accuracy for applications requiring precise low-volume dispensing.
  • Manual operation requires technique: As a manual air-displacement pipette, accuracy depends on consistent user technique, pipetting speed, and proper calibration, unlike electronic pipettes.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).