Mi-Pette Single-channel 100-1000 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette is a manually operated liquid handling device that requires adherence to sterilization, calibration, and tip compatibility constraints. Failure to follow these constraints may result in inaccurate volume delivery, contamination, or damage to the instrument.
- Sterilization Constraint: The pipette must be sterilized via high-temperature autoclaving only if the product family documentation explicitly supports such treatment; otherwise, alternative sterilization methods should be employed.
- Calibration Constraint: The pipette must be calibrated according to ISO 8655-2 using the specified test volumes (1000, 500, 100 µL) to ensure systematic and random errors remain within the stated tolerances.
- Tip Compatibility Constraint: Only tips that are compatible with the 100-1000 µL range, provide a secure and stable fit, and are designed for the pipette's tip cone should be used to avoid leakage or inaccurate aspiration.
How does the systematic error of the Mi-Pette 100-1000 µL pipette vary across its volume range, and what is the impact on low-volume accuracy?
The systematic error degrades significantly at the lower end: at 1000 µL it is ±8 µL (±0.8%), at 500 µL ±8 µL (±1.6%), and at 100 µL ±8 µL (±8.0%). This means relative accuracy is poorest near 100 µL, where the error is 8% of the set volume. Random error also increases from ±3 µL (±0.3%) at 1000 µL to ±3 µL (±3.0%) at 100 µL, making the pipette less suitable for high-precision applications at low volumes.
What calibration standard applies to the Mi-Pette 100-1000 µL pipette, and how does it affect routine method validation?
The pipette is calibrated to the ISO 8655-2 user calibration reference for piston-operated volumetric apparatus. This standard defines the calibration procedure and acceptance criteria, which must be followed for method validation and routine performance review. Users should confirm compatible tips and calibration requirements before assay setup to maintain traceability.
What sterilization methods are supported for the Mi-Pette 100-1000 µL pipette, and are there any limitations?
The Mi-Pette is a fully autoclavable manual pipette, supporting high-temperature sterilization where indicated by the source family. Users should verify sterilization suitability for their specific workflow, as the technical table notes that high-temperature sterilization is supported only where indicated by the source family. Confirm with the supplier if sterilization cycles are required for your application.
The Mi-Pette Single-channel 100-1000 µL pipette offers a fully autoclavable design with ISO 8655-2 calibration traceability but exhibits significantly higher relative systematic and random errors at its lower test volume of 100 µL compared to mid-range performance.
Positive
- Fully autoclavable construction: High-temperature sterilization is supported as indicated by the product family, enabling decontamination between uses without disassembly.
- ISO 8655-2 calibration reference: The pipette includes a user calibration reference per ISO 8655-2 standard, providing traceable performance data for method setup and routine quality control.
Trade-offs
- High systematic error at low volume: At the 100 µL test volume systematic error is ±8 µL (±8.0%), which limits accuracy for small-volume transfers compared to mid-range performance.
- Elevated random error at low volume: Random error at 100 µL is ±3 µL (±3.0%), reducing reproducibility in precise applications such as serial dilutions or PCR setup.