Mi-Pette Single-Channel Pipette 5-50 μL, 0.05 μL ATOMFAIR®

$58.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Single-channel Mi-Pette manual pipette, 5-50 µL with 0.05 µL increment, ISO 8655-2 calibration reference, and autoclavable design. Order now.

SKU: AF-EI-L-MIPT-E050-SC00
Category: ,
Tags:
Brands:

Description

Mi-Pette Single-channel 5-50 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette Single-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-5-50-µL
Product Family Mi-Pette
Channel count Single-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error At 50 µL: ±0.5 µL (±1.0%); at 25 µL: ±0.5 µL (±2.0%); at 5 µL: ±0.5 µL (±10%)
Random error At 50 µL: ±0.25 µL (±0.5%); at 25 µL: ±0.25 µL (±1.0%); at 5 µL: ±0.25 µL (±5.0%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette must be calibrated per ISO 8655-2 and sterilized by high-temperature autoclaving after use. Tip compatibility must be confirmed to maintain accuracy and prevent cross-contamination.

  • Calibration Requirement: Calibration must be performed at the three test volumes (50, 25, 5 µL) with systematic error within ±0.5 µL and random error within ±0.25 µL as per ISO 8655-2.
  • Sterilization Procedure: High-temperature sterilization is supported; follow manufacturer instructions for disassembly and autoclave cycle parameters.
  • Tip Compatibility: Only compatible pipette tips should be used to ensure proper seal and volumetric accuracy.

How does the accuracy of the Mi-Pette 5-50 µL pipette change across its volume range, particularly at the low end?

The systematic error at 5 µL is ±0.5 µL (±10%), while at 50 µL it is ±0.5 µL (±1.0%). The random error is ±0.25 µL (±5.0%) at 5 µL and ±0.25 µL (±0.5%) at 50 µL, as specified in the technical table. Users should expect significantly higher relative uncertainty when pipetting at the lower end of the range.

What are the compatibility requirements for tips and calibration when using the Mi-Pette 5-50 µL pipette?

The product description advises confirming compatible tips before ordering, as the pipette is designed for a single-channel format with a 5-50 µL working range. Calibration should follow ISO 8655-2, and the pipette supports user calibration as indicated in the technical table. The pipette is suitable for manual liquid handling in PCR, serial dilution, and routine transfer.

Can the Mi-Pette 5-50 µL pipette be sterilized by autoclaving, and what are the maintenance requirements?

The pipette supports high-temperature sterilization where indicated by the source family, as noted in the specifications. The technical table includes a calibration reference per ISO 8655-2, and the configuration support advises confirming sterilization needs before ordering. Regular calibration and proper tip selection are recommended for reliable performance.

The Mi-Pette Single-channel 5-50 µL pipette offers autoclavable construction and ISO 8655-2 calibration traceability, but exhibits a ±10% systematic error at the 5 µL minimum volume and requires user verification of tip compatibility and sterilization parameters.

Positive

  • Fully autoclavable for sterility: The pipette supports high-temperature sterilization, enabling decontamination between uses in microbiology and molecular biology workflows.
  • Precise volume increment with specified error rates: The 0.05 µL increment and published systematic/random error at each test volume allow method validation and calibration tracking per ISO 8655-2.

Trade-offs

  • High relative systematic error at minimum volume: At 5 µL, systematic error is ±10% (0.5 µL), which may limit accuracy for low-volume applications requiring tighter tolerance.
  • Requires user calibration and tip compatibility confirmation: The pipette relies on user calibration reference and compatible tips, and sterilization suitability must be confirmed per source family, adding pre-deployment setup steps.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).