Description
HiPette-LTS Single-channel 10-100 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires routine calibration per ISO 8655-2 to maintain stated accuracy across its test volumes. Sterilization must be performed exclusively via full autoclaving; incompatible tips or improper sterilization may compromise mechanical integrity and performance.
- Calibration requirement: Calibration must be performed at 100 µL, 50 µL, and 10 µL to verify systematic and random error tolerances.
- Sterilization constraint: Only full autoclaving (121°C, 20 minutes) is approved; dry heat, UV, or chemical sterilants are not compatible.
- Tip compatibility: Use only tips certified for the HiPette-LTS system to ensure hermetic seal and volumetric accuracy.
How does the systematic error of the HiPette-LTS 10-100 µL pipette change across the volume range, and what impact does this have on low-volume assays?
The systematic error is ±0.80 µL (±0.8%) at 100 µL, ±0.50 µL (±1.0%) at 50 µL, and ±0.30 µL (±3.0%) at 10 µL. This means that at low volumes near 10 µL, the relative error is significantly higher, which may affect precision in applications such as PCR setup or small-volume reagent addition.
What calibration standard is referenced for the HiPette-LTS, and what should users verify before integrating it into a method?
The pipette is calibrated to ISO 8655-2 user calibration reference. Users should confirm compatible tips, calibration requirements, and sterilization needs before ordering, as the product description indicates that configuration support is recommended for method-specific volume matching.
Is the HiPette-LTS pipette fully autoclavable, and what are the considerations for sterilization in a research laboratory?
Yes, the pipette is fully autoclavable for sterilization. However, the product description does not specify cycle parameters; users should follow standard laboratory sterilization protocols for micropipettes and ensure that the pipette is compatible with their autoclave's temperature and pressure settings.
The HiPette-LTS Single-channel 10-100 µL pipette offers fully autoclavable construction and good accuracy at the upper end of its range, but users should note the increased systematic error at low volumes and the need for regular calibration and proper technique.
Positive
- Fully autoclavable for sterile workflows: The entire pipette can be autoclaved, eliminating cross-contamination risk in microbiological, PCR, and cell culture applications.
- Low error at full volume (100 µL): At 100 µL, systematic error is ±0.8% and random error ±0.2%, ensuring repeatable and accurate liquid transfers for routine analytical methods.
Trade-offs
- Higher systematic error at low volumes: At 10 µL, systematic error increases to ±3.0%, which may compromise precision for sub-50 µL applications requiring tighter tolerances.
- Manual calibration and technique dependency: Optimal performance relies on user pipetting technique and periodic calibration per ISO 8655-2, adding operational overhead for consistency.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).