Description
3.20V 160Ah LFP Prismatic Cell | ATOMFAIRCOMMERCIAL GRADE · PRODUCTION
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: INQUIRY@ATOMFAIR.COM
|
|||||||||||||||||||||||||
|
Manufacturer: ATOMFAIR LLC
Brand: ATOMFAIR®
|
This document outlines essential handling and storage constraints for the ATOMFAIR LFP prismatic cell. Adherence to these limits ensures safe operation and prevents degradation.
- Storage Conditions: Store the cell in a dry environment at room temperature away from conductive materials to prevent short circuits.
- Charge Rate Limit: Do not charge the cell at a continuous current exceeding 320A to remain within the specified 2C maximum rate.
- Discharge Rate Limit: Do not discharge the cell at a continuous current exceeding 160A to comply with the 1C maximum discharge rate.
- Cycle Life Consideration: The cell achieves a minimum of 5000 cycles at 25°C when operated within 2C/1C limits at 100% depth of discharge.
Follow these steps to safely prepare and deploy the 160Ah LFP cell for traction applications. Proper initial handling ensures performance and longevity.
Required Equipment: LFP-compatible battery charger
- Inspect Cell
Inspect the prismatic cell casing for any dents, swelling, or leakage prior to handling. - Confirm Charger Compatibility
Confirm the charger is designed for LFP chemistry and set to the appropriate voltage limit for a single cell. - Connect to BMS
Connect the cell terminals to a battery management system ensuring correct polarity and secure contacts. - Charge Cell
Charge the cell at a continuous current not exceeding 320A until the cell reaches full charge. - Discharge Test
Discharge the cell at a continuous current not exceeding 160A to verify capacity and connection integrity.
What is the cycle life trade-off when operating this 160Ah LFP prismatic cell at 2C continuous charge versus the standard 1C rate?
This cell achieves ≥5000 cycles at 2C charge and 1C discharge, 100% DOD, with 70% capacity retention, as tested at 25°C. Operating at the maximum 2C charge rate does not degrade the specified cycle life, but exceeding this rate or operating outside the recommended temperature range will reduce longevity. The manufacturer notes that cycle life testing was performed under 5C/1.0C conditions for retention verification, indicating robust tolerance to high-rate cycling.
Can this 33.3mm thick prismatic LFP cell be integrated into an existing 48V or 96V traction pack without custom busbar modifications?
Yes, with appropriate series-parallel configurations, but the 33.3 × 200.6 × 210.0 mm dimensions require a pack design that accommodates the square aluminum case and terminal layout. The nominal 3.20V voltage per cell means 15 cells in series achieve 48V nominal, and 30 cells achieve 96V. A dedicated BMS with over-discharge, over-charge, short-circuit, and cell balancing protection is mandatory for safe integration into any traction application.
What are the storage and handling requirements to prevent capacity fade before first use?
Store cells in humidity-controlled, vacuum-sealed packaging as supplied, with individual isolation in anti-static foam lined cartons. Pre-condition cells at a suitable temperature before first use, and avoid mechanical deformation or short circuits. Operate within the recommended temperature range for optimal cycle life and dispose according to local regulations.
The ATOMFAIR 3.20V 160Ah LFP prismatic cell delivers a high energy density of 170 Wh/kg and a cycle life of ≥5000 cycles at 100% DOD, enabling fast 2C charging for traction applications. Deployment requires a dedicated BMS and strict temperature control to maintain the rated longevity.
Positive
- 2C Continuous Fast Charge Rate: Supports a 2.0C continuous charge rate, significantly reducing EV charging time and enabling high-uptime fleet operations.
- ≥5000 Cycle Life at 100% DOD: Provides ≥5000 cycles at 2C charge / 1C discharge, 100% depth of discharge, with 70% capacity retention, ensuring durability for high-utilization traction systems.
Trade-offs
- Mandatory External BMS Required: Integration necessitates a dedicated battery management system for over-discharge, over-charge, short-circuit protection, and cell balancing, adding system-level cost and design complexity.
- Temperature Sensitivity for Cycle Life: Optimal cycle life and performance depend on storage and operation within the manufacturer-recommended temperature range; thermal preconditioning before first use is required.