Atomfair IR-Oil 770 Infrared Oil Analyzer
Product Overview
Atomfair IR-Oil 770 is a professional oil analyzer developed in accordance with international testing standards, featuring compact size, light weight, integrated optical system design, excellent stability and high signal-to-noise ratio. It is suitable for the determination of petroleum, animal and vegetable oils in industrial wastewater, domestic sewage, oil fume, oil mist and soil, providing accurate and reliable testing solutions for environmental monitoring, water quality analysis and soil testing scenarios.
Core Advantages
1. Dual-purpose & Flexible Adaptation: Adopt cast aluminum alloy base with natural aging treatment, small size and light weight (only 13KG). It can be used as a fixed laboratory instrument or a portable device for on-site testing, suitable for multi-scenario testing needs.
2. Stable & Accurate with Reliable Data: Equipped with integrated optical system with short optical path and high energy, strong stability and high signal-to-noise ratio. The original automatic switching mechanism between sample cell and reference cell can realize precise positioning, eliminate errors, stabilize measurement results and achieve automatic zero adjustment.
3. Precise & Efficient Wave Number Positioning: Adopt cosecant principle for precise wave number positioning and scanning, the wave number positioning accuracy is < 1 wave number, wave number accuracy and repeatability both reach ±1cm⁻¹ to ensure the accuracy of detection data.
4. Practical Performance with Controllable Error: Simulate oil components in water, the measurement error of standard oil with any composition is < 5%, which can effectively meet the actual testing needs of water samples, soil, oil fume and oil mist samples.
5. Convenient Operation & Intelligent: Equipped with large screen color LCD touch display, supporting stand-alone operation and computer connection. Full wave number measurement with real-time spectrum display for users to fully grasp sample information. Equipped with proprietary oil testing software (software copyright applied), integrating spectrum scanning, analysis, calculation and storage to simplify the operation process.
Technical Parameters
Technical Index Specification Parameters
Wave Number Scanning Range 3400~2400cm⁻¹
Wave Number Accuracy ±1cm⁻¹
Wave Number Repeatability ±1cm⁻¹
Detection Limit ≤0.02mg/L
Measurement Repeatability <2%
Measurement Accuracy ±2%
Absorbance Linear Range 0.0000~1.9999AU
Measurement Range (Enriched Oil Concentration in Water) 0.02~800mg/L
Minimum Detectable Concentration (Enriched Oil Concentration in Water) 0.002mg/L
Baseline Drift <1%/4h
Measurement Error of Different Ratios <5%
Communication Interface RS232, USB
Overall Dimension (mm) 540×246×160
Weight (Kg) 13
Power Supply 220V±20V, 50Hz±1Hz, 40W
Working Humidity <80%
Working Temperature 5~35°C
If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.
The instrument must be operated within a temperature range of 5 to 35°C and relative humidity below 80% to ensure measurement accuracy. It requires a stable power supply of 220V ±20V at 50Hz ±1Hz with a maximum power consumption of 40W.
- Temperature Constraint: Operate the analyzer only within the specified ambient temperature range of 5 to 35°C to prevent drift and maintain performance.
- Humidity Constraint: Maintain relative humidity below 80% during operation and storage to avoid condensation and optical degradation.
- Power Supply Requirement: Connect the instrument to a grounded power source supplying 220V ±20V at 50Hz ±1Hz with sufficient capacity for its 40W rating.
How does the IR-Oil 770 achieve a measurement error of less than 5% when analyzing different oil compositions?
The analyzer simulates oil components in water and the measurement error of standard oil with any composition is less than 5%. This ensures reliable results for water, soil, oil fume, and oil mist samples, as stated in the product's performance specifications.
What communication interfaces does the IR-Oil 770 provide for data transfer and software integration?
The IR-Oil 770 is equipped with RS232 and USB communication interfaces. It comes with proprietary oil testing software that integrates spectrum scanning, analysis, calculation, and storage, enabling both stand-alone operation and connection to a computer for advanced data handling.
What are the environmental and power requirements for operating the IR-Oil 770 in both laboratory and field settings?
The analyzer operates at 5–35°C with humidity below 80% and requires a power supply of 220V±20V, 50Hz±1Hz, consuming 40W. Despite its lightweight (13 kg) and compact design (540×246×160 mm) that allow portable use, a stable 220V AC power source is necessary even for on-site testing.
The Atomfair IR-Oil 770 Infrared Oil Analyzer delivers a compact, dual-purpose optical system with a 3400–2400 cm⁻¹ scanning range, achieving ±1 cm⁻¹ wave number accuracy and a 0.02 mg/L detection limit, making it suitable for field and laboratory oil-in-water analysis. Its integrated optical design and automatic cell switching ensure stable, repeatable measurements, though operation requires controlled environmental conditions and a stable power supply.
Positive
- High wave number accuracy and repeatability: Wave number positioning accuracy is <1 cm⁻¹ with accuracy and repeatability of ±1 cm⁻¹, ensuring precise spectral scanning and reliable compound identification across the 3400–2400 cm⁻¹ range.
- Portable dual-purpose design: The cast aluminum alloy base keeps weight at 13 kg, enabling use as a fixed laboratory instrument or a portable field device, with a compact footprint of 540×246×160 mm for flexible deployment.
Trade-offs
- Environmental sensitivity: Operation is restricted to 5–35°C and <80% humidity, requiring controlled ambient conditions to maintain baseline drift below 1%/4h and measurement accuracy.
- Power supply dependency: The instrument requires a stable 220V±20V, 50Hz±1Hz supply at 40W, which may necessitate voltage regulation or an uninterruptible power supply in field or unstable grid environments.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).