Atomfair IR-Fume 930 Fully Automated Oil Mist Tester, ±1cm⁻¹ Wave Accuracy, ≤0.05mL Dosing Error, 20min Fast Single Sample Test

Atomfair IR-Fume 930 is a fully automatic oil fume/mist analyzer with ±1cm⁻¹ accuracy,

Description





Atomfair IR-Fume 930 Automatic Oil Fume & Mist Analyzer

Atomfair IR-Fume 930 Automatic Oil Fume & Mist Analyzer

Product Overview

Atomfair IR-Fume 930 is a professional fully automatic analyzer developed in accordance with international standards, specialized in measuring oil fume and oil mist in exhaust gas. Adopting ultrasonic extraction technology and fully automated workflow, it has high extraction efficiency, excellent stability and precise detection performance. Widely applicable to laboratory and on-site testing in petroleum, petrochemical, smelting, environmental protection, catering and other industries, it provides efficient, safe and reliable testing solutions for exhaust gas pollution monitoring.

Core Advantages

1. Fully Automatic Unattended Operation: Automatically complete the whole process including tetrachloroethylene purity inspection, extractant addition, liquid-liquid extraction, filter cartridge cleaning, sample constant volume, oil content measurement, pipeline cleaning and reagent recovery without manual intervention, saving worry and high efficiency.

2. Ultra-precise Detection Performance: Wave number accuracy and repeatability both reach ±1cm⁻¹, mechanical positioning error < 1 wave number; detection error of standard samples with different ratios < 3%, which can effectively detect benzene and toluene; high-precision syringe pump ensures sample addition error < 0.05mL with accurate and reliable data.

3. Strong Adaptability to Complex Samples: With automatic over-range dilution function, high concentration samples can be automatically diluted to ensure accurate measurement results; ultrasonic extraction method with extraction efficiency up to 98%, fully adapting to the detection needs of various oil fume and oil mist samples.

4. Extremely Low Cross Contamination: Independent pipeline design for reagent adding, sampling and waste discharge to avoid cross contamination; after testing each sample, the instrument automatically cleans the cuvette and the entire pipeline system to minimize the risk of contamination.

5. Intelligent and Convenient Operation: Equipped with 10.1-inch Windows 10 tablet computer, which can be flexibly removed for remote control, and the host reserves external computer communication interface; full wave number measurement with real-time spectrum display, supporting quantitative measurement and qualitative analysis; special software integrates user management, sample measurement, spectrum scanning, historical data query and data printing functions.

6. Safe and Environmental Protection Design: Fully closed pipeline design to avoid staff contact with tetrachloroethylene, no need to use in fume hood; automatic reagent recovery to ensure operational safety and environmental friendliness.

7. Stable, Reliable and Durable: Cast aluminum base treated with natural stress aging, with excellent optical stability; zero tracking technology eliminates the influence of mechanical errors and temperature drift; with self-inspection and process fault judgment functions, automatic fault prompt when failure occurs for easy maintenance.

8. Efficient Multi-sample Detection: Support 5/10 sample positions (configurable), can freely set 1-N discontinuous sample positions; multi-channel simultaneous extraction greatly improves work efficiency, and the single sample detection time is only 20 minutes.

Technical Parameters

Technical Index    Specification Parameters

Wave Number Scanning Range    3400cm⁻¹~2400cm⁻¹

Wave Number Accuracy    ±1cm⁻¹

Wave Number Repeatability    ±1cm⁻¹

Method Detection Limit    <0.02mg/m³

Lower Limit of Determination    0.05mg/m³

Repeatability    ±2%

Accuracy    ±2%

Absorbance Range    0-1.9999

Sample Addition Error    ≤0.05mL

Measurement Range    0-300mg/m³

Sample Positions    5/10 (Configurable)

Extraction Method    Ultrasonic Extraction

Reagent Purity Inspection    Automatic

Sample Detection Time    20 minutes

Overall Dimension (mm)    600×400×650

Weight (Kg)    20

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.