Description
TopPette Single-channel 5-50 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette requires routine calibration per ISO 8655-2 to maintain specified systematic and random error limits. The lower half is autoclavable, and tip compatibility must be confirmed before use.
- Calibration Requirement: Routine calibration against ISO 8655-2 at test volumes 5, 25, and 50 µL is required to maintain the documented accuracy and precision.
- Sterilization Constraint: Only the lower half of the pipette can be autoclaved; sterilization parameters must be validated to avoid damage to the instrument.
- Tip Compatibility: Compatible tips must be selected to ensure a secure seal and accurate volume delivery.
- Error Verification: Systematic error and random error at each test volume must be verified during calibration to confirm the pipette meets specifications.
How does the accuracy of the TopPette 5-50 µL pipette change when operating at the lower end of its volume range compared to the upper end?
At the upper end (50 µL), the systematic error is ±0.9%, while at the lower end (5 µL) it increases to ±3.0%. Random error also varies, from ±0.3% at 50 µL to ±1.6% at 5 µL. This performance trade-off should be considered when pipetting near the minimum volume.
What calibration standard does the TopPette 5-50 µL pipette reference, and how does that affect its use in regulated laboratory workflows?
The pipette references ISO 8655-2 for user calibration. Systematic and random error values are provided at three test volumes (50, 25, 5 µL) to support method setup and routine performance review. This allows integration into quality-controlled processes that require traceable calibration data.
Can the TopPette 5-50 µL pipette be autoclaved for sterilization, and what are the specific limitations?
Only the lower half of the pipette is autoclavable where indicated; full sterilization is not possible. Users should confirm the sterilization suitability for their specific workflow before use. This limitation affects decontamination protocols in biosafety level applications.
TopPette Single-channel 5-50 µL pipette offers accurate liquid handling for low-volume workflows with autoclavable lower assembly and ISO-referenced calibration. However, the upper assembly is not autoclavable and the relative error increases significantly at lower test volumes.
Positive
- Single-channel precision for microliter workflows: Single-channel configuration supports accurate single-tube sample preparation, reagent addition, and PCR setup with a 0.05 µL increment for fine volume adjustment.
- Autoclavable lower assembly for sterility: Lower half of the pipette is autoclavable where indicated, allowing decontamination between uses in sensitive applications.
Trade-offs
- Lower relative accuracy at small volumes: Systematic error at 5 µL is ±3.0%, significantly higher than at full volume, which may affect precision at the low end of the range.
- Partial autoclavability restriction: Only the lower half is autoclavable where indicated; the upper assembly is not autoclavable, limiting complete sterilization options.