Three-Zone Sliding Tube Furnace TF-1200-0V 1200°C ATOMFAIR®

$13,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Three-zone 1200°C tube furnace with two-way sliding rapid-cooling design, 7 kW, AC 208-240 V, and vacuum/gas capability for annealing, sintering and CVD.

SKU: AF-TF-M-1200-AX04-000V
Category:
Tags: , , ,
Brands:

Three-Zone Sliding Rapid-Heating Tube Furnace, 1200 °C
LABORATORY THERMAL PROCESSING EQUIPMENT
Product Overview

Three-Zone Sliding Rapid-Heating Tube Furnace, 1200 °C is a vacuum/atmosphere tube furnace for controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development.

The configuration focuses on zones sliding rapid heating tube furnace.

Additional configuration points include Used for big size graphene film growing with double tubes inside& outside, also for CVD experiment with RTP requirement.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model TF-1200-0V
Product Family vacuum/atmosphere tube furnace
Configuration Focus zones sliding rapid heating tube furnace.
Process Fit controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development
Quotation Confirmation Confirm temperature class, tube or chamber size, heating-zone layout, gas/vacuum package, power supply and required accessories.
Configuration Highlights
  • zones sliding rapid heating tube furnace.
  • Used for big size graphene film growing with double tubes inside& outside, also for CVD experiment with RTP requirement.
  • With two-way slide, shuffle the furnace to pull out the sample to achieve rapid cooling after growing.
  • Power rated: 7KW 208-240V.
  • Voltage rated: AC208-240V 50/60Hz.
APPLICATION SCOPE: controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging for handling, storage and delivery.
IMPORTANT NOTICE: Please confirm temperature class, usable process size, gas/vacuum package, power supply and accessory configuration before quotation.
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This furnace requires a dedicated AC208-240V 50/60Hz power supply rated at 7KW. Operation must be performed with confirmed temperature class, tube size, gas/vacuum package, and accessory configuration to ensure safe thermal processing.

  • Electrical Supply: Connect the furnace to a dedicated AC208-240V 50/60Hz circuit rated for at least 7KW to prevent overloading.
  • Temperature Class Confirmation: Verify the required temperature class and usable process size before initiating any heating cycle.
  • Gas/Vacuum Package: Ensure the gas/vacuum package is correctly configured for the intended process atmosphere to avoid contamination or hazard.
  • Rapid Cooling Procedure: Use the two-way slide mechanism to pull out the sample for rapid cooling after growth, but only after confirming safe handling temperatures.
  • Accessory Configuration: Confirm all accessory configurations, including tube and heating-zone layout, are compatible with the planned thermal process.

This procedure outlines the steps to initialize, load, and execute a thermal process with rapid cooling. Proper configuration and safety checks are required before each run.

Required Equipment: Three-Zone Sliding Rapid-Heating Tube Furnace, Two-way slide mechanism, Gas/vacuum supply system, Temperature controller

  1. Inspect power supply
    Inspect the furnace and confirm that the power supply matches the required AC208-240V 50/60Hz 7KW rating.
  2. Configure gas/vacuum
    Configure the gas/vacuum package according to the process atmosphere requirements and verify all connections are secure.
  3. Load sample
    Load the sample into the inner tube and position the furnace zones as needed for the thermal profile.
  4. Set temperature program
    Set the temperature controller to the desired heating program and initiate the ramp.
  5. Execute rapid cooling
    Monitor the process and after the growth phase, activate the two-way slide to pull the sample out for rapid cooling.
  6. Cool down furnace
    Allow the furnace to cool down to safe handling temperature before opening the chamber.

How does the three-zone sliding rapid-heating tube furnace achieve rapid cooling for graphene film growth?

The furnace uses a two-way sliding mechanism to shuffle the furnace and pull out the sample after heating, enabling rapid cooling. This design, combined with three-zone heating and double tubes (inside and outside) for large-area graphene film growth, allows controlled thermal profiles essential for CVD and RTP processes. The furnace operates at 1200°C with a power rating of 7KW at 208-240V.

Can the Atomfair TF-1200-0V tube furnace be used for chemical vapor deposition (CVD) with rapid thermal processing (RTP) requirements?

Yes, the furnace is specifically designed for CVD experiments with RTP requirements, as stated in its configuration highlights. It features double tubes (inside and outside) for large-size graphene film growth and a sliding rapid-heating mechanism to control temperature ramps and cooling rates, meeting the demands of both CVD and RTP applications.

What are the electrical and configuration requirements for the Three-Zone Sliding Rapid-Heating Tube Furnace 1200°C?

The furnace requires a power supply of 7KW at AC208-240V, 50/60Hz. Before quotation, users must confirm temperature class, tube or chamber size, heating-zone layout, gas/vacuum package, and power supply to ensure proper configuration. The equipment is prepared with protective inner materials and reinforced outer packaging for safe handling and delivery.

The Three-Zone Sliding Rapid-Heating Tube Furnace (1200°C) enables rapid cooling via a two-way slide mechanism, suitable for large-area graphene film growth and CVD with RTP requirements, but requires a dedicated 208-240V/7kW power supply and separate gas/vacuum system configuration.

Positive

  • Two-way slide rapid cooling: The two-way sliding mechanism allows the furnace to be moved away from the sample for rapid cooling, enabling quench-type thermal profiles critical for graphene film growth and RTP CVD processes.
  • Double tube for large-area graphene: The double-tube configuration (inner and outer) supports large-size graphene film synthesis by providing uniform gas flow and thermal environment across a wider substrate area.

Trade-offs

  • High power demand: Rated at 7 kW on 208-240V, the furnace requires a dedicated high-current electrical circuit, which may necessitate lab infrastructure upgrades for standard 120V outlets.
  • Gas/vacuum package not included: The gas handling and vacuum systems are not pre-configured; buyers must specify and procure these separately, adding to initial setup complexity and cost.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Related Products