Straight Five-Port Electrolytic Cell Double-Layer ATOMFAIR®

Price range: $197.00 through $548.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade double-layer straight five-port electrolytic cell with absolute sealing, 10mL-1000mL capacity and vacuum below -100kPa. Order now.

Straight Five-Port Electrolytic Cell, Absolute Sealing, Double-Layer | ATOMFAIR

Product Type: Electrochemical cell
Research-grade laboratory product

Product Overview

The ATOMFAIR® Double-Layer Absolute Sealing Straight Five-Port Electrolytic Cell is constructed from high-borosilicate glass and designed as an absolutely sealed system for three-electrode applications. The cell volume ranges from 10mL to 1000mL, with custom capacities available upon request. Electrode connections are achieved via built-in jacks on the lid, enabling complete internal electrode integration and absolute sealing of the three-electrode system. The cell is equipped with valves and a sparger for gas protection and atmosphere control. Vacuum capability (below -100kPa) is supported, and pressurization (up to 0.5MPa) is available only with round-bottom designs for safety. The double-layer version incorporates a thermostatic water bath jacket for precise temperature control. Please note: The double-layer configuration cannot be pressurized due to the thinner inner glass wall. Electrodes must be purchased as matched sets with this cell model. This cell does not support salt bridges, sintered frits, or Luggin capillaries; only Ag/AgCl reference electrodes are compatible.

Performance Features

  • Absolutely sealed design: Internal electrode jacks on the lid provide complete sealing integrity, ideal for oxygen- and moisture-sensitive experiments.
  • Integrated water bath jacket: Double-layer design enables precise thermal regulation for temperature-dependent electrochemical studies.
  • Vacuum and pressure capability: Supports vacuum below -100kPa and pressurization up to 0.5MPa (round-bottom design required for pressure applications).
  • Built-in gas management: Valves and sparger allow efficient inert gas purging and atmosphere protection.
  • High-borosilicate glass construction: Excellent chemical resistance and thermal stability across a wide range of electrolytes.

Technical Specifications

Parameter Specification / Available Values
Product Family Straight Five-Port Electrolytic Cell, Absolute Sealing, Double-Layer
Atomfair Model AF-C002-010-DBL
 Configuration 10ml
Atomfair Model AF-C002-030-892
 Configuration 30ml
Atomfair Model AF-C002-050-495
 Configuration 50ml
Atomfair Model AF-C002-100-680
Configuration 100ml
Atomfair Model AF-C002-150-525
Configuration 150ml
Atomfair Model AF-C002-200-140
Configuration 200ml
Atomfair Model AF-C002-250-FE5
Configuration 250ml
Atomfair Model AF-C002-500-03E
Configuration 500ml
Atomfair Model AF-C002-000-B95
Configuration 1000ml
APPLICATION SCOPE: Strictly anaerobic electrochemistry, vacuum electrochemical studies, pressurized electrochemical testing (round-bottom required, ≤0.5MPa), battery and fuel cell research, and air-sensitive materials characterization.
PACKAGING: Individual shock-proof packaging with specialized foam lining and reinforced cartons to ensure the glass body remains intact during transportation.
IMPORTANT NOTICE: Ensure proper electrode pairing and seal integrity before use. Verify compatibility with your experimental conditions and reference electrode type. Consult factory for pressure applications.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This cell requires absolute sealing for air-sensitive experiments and uses only Ag/AgCl reference electrodes. The double-layer configuration prohibits pressurization; temperature control is achieved via the integrated water bath jacket.

  • Sealing Integrity: The cell's internal electrode jacks and lid design provide complete sealing, critical for oxygen- and moisture-sensitive electrochemistry.
  • Reference Electrode Compatibility: Only Ag/AgCl reference electrodes are compatible; salt bridges, sintered frits, and Luggin capillaries are not supported.
  • Gas Management Requirements: Built-in valves and sparger enable inert gas purging and atmosphere control for anaerobic experiments.
  • Temperature Regulation: The double-layer jacket requires connection to a thermostatic water bath for precise temperature control during experiments.
  • Vacuum and Pressure Limitations: The cell supports vacuum below -100 kPa but the double-layer design cannot be pressurized; round-bottom pressurization is not available for this variant.

This procedure ensures proper sealing, electrode integration, and atmosphere control for air-sensitive electrochemical experiments. All steps must be performed in a clean, dry environment to prevent contamination.

Required Equipment: Inert gas supply (e.g., argon or nitrogen), Thermostatic water bath, Vacuum pump capable of < -100 kPa, Matched Ag/AgCl reference electrode set

  1. Verify electrode compatibility
    Confirm that the reference electrode is of the Ag/AgCl type and that the electrode set matches this cell model.
  2. Seal the lid onto the cell
    Seal the lid onto the cell body, ensuring that the O-ring is properly seated and the internal electrode jacks are fully engaged.
  3. Purge with inert gas
    Connect the sparger to an inert gas line and begin purging to establish an oxygen- and moisture-free atmosphere.
  4. Connect water bath for temperature control
    Attach the water bath hoses to the double-layer jacket and set the thermostat to the desired experimental temperature.
  5. Test vacuum seal integrity
    Apply vacuum below -100 kPa and verify that the system holds the pressure without leakage before introducing electrolyte.

Can the double-layer (water jacket) version of the straight five-port electrolytic cell be used for pressurized experiments?

No, the double-layer configuration cannot be pressurized. The thinner inner glass wall required for the thermostatic water jacket precludes pressurization. For pressurized applications up to 0.5MPa, a round-bottom design is required, but this is not available on the double-layer version. If temperature control and pressure are both needed, a different cell configuration must be selected.

What reference electrodes are compatible with this absolutely sealed electrolytic cell?

Only Ag/AgCl reference electrodes are compatible. The cell design does not support salt bridges, sintered frits, or Luggin capillaries. Electrodes must be purchased as matched sets specifically for this cell model to maintain the absolute sealing integrity required for oxygen- and moisture-sensitive experiments.

What are the vacuum and pressure limits for this straight five-port electrolytic cell?

The cell supports vacuum below -100kPa. Pressurization up to 0.5MPa is possible only with round-bottom designs; the double-layer version cannot be pressurized due to the thinner inner glass wall. Proper electrode pairing and seal integrity must be verified before use. For pressure applications, consult the factory and select the round-bottom variant.

This double-layer absolute sealing electrolytic cell provides complete sealing integrity for anaerobic and moisture-sensitive three-electrode experiments, with an integrated water bath jacket enabling precise thermal regulation, but cannot be pressurized due to thinner inner glass walls and only supports Ag/AgCl reference electrodes.

Positive

  • Absolute sealing integrity: Internal electrode jacks on the lid provide complete sealing, ideal for oxygen- and moisture-sensitive electrochemical experiments.
  • Integrated water bath jacket: Double-layer design enables precise thermal regulation for temperature-dependent electrochemical studies.

Trade-offs

  • No pressurization for double-layer: The double-layer configuration cannot be pressurized due to the thinner inner glass wall, limiting high-pressure applications to round-bottom designs only.
  • Limited reference electrode compatibility: Only Ag/AgCl reference electrodes are compatible; salt bridges, sintered frits, and Luggin capillaries are not supported.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Capacity / Size

10mL, 30mL, 50mL, 100mL, 150mL, 200mL, 250mL, 500mL, 1000mL

Related Products