Small Sliding Sample Tube Furnace, 1700 °C
LABORATORY THERMAL PROCESSING EQUIPMENT
|
|||||||||||||||||||
|
|||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The furnace operates with a maximum temperature of 1700°C and requires compatible quartz or ceramic tube materials. Vacuum integrity and proper gas supply configuration must be verified before operation to prevent hazards.
- Temperature Limit: Do not exceed the maximum rated temperature of 1700°C to avoid damage to heating elements or the tube.
- Tube Material Compatibility: Use only quartz or ceramic tubes that are rated for the intended temperature and atmosphere conditions.
- Vacuum Integrity: Ensure all vacuum flanges are properly sealed and the system is leak-free before evacuation.
- Atmosphere Gas Flow: Supply flowing gas at the correct pressure and flow rate as specified for the thermal process.
- Configuration Confirmation: Confirm the temperature class, tube size, gas/vacuum package, and power supply before operation to ensure safe configuration.
This procedure describes the safe initialization and operation of the furnace for controlled heating under vacuum or flowing gas. Follow these steps to set up the tube, connect utilities, and run the thermal process.
Required Equipment: Small Sliding Sample Tube Furnace, 1700°C
- Install Tube
Install a compatible quartz or ceramic tube into the furnace, ensuring it is correctly seated and aligned. - Connect Utilities
Connect the vacuum or gas supply lines to the vacuum flanges and verify proper sealing. - Set Temperature
Set the desired temperature up to 1700°C on the controller using the furnace's interface. - Initiate Process
Initiate the heating, vacuum, or gas flow process and monitor the furnace for stable operation. - Cool Down and Unload
Allow the furnace to cool to a safe temperature before opening and removing the sample.
What is the maximum operating temperature of the Atomfair TF-1700-0L tube furnace, and which tube materials are recommended for 1700°C operation?
The Atomfair TF-1700-0L is rated for 1700°C. The product family highlights quartz or ceramic tube arrangements for high-temperature operation. The specific tube material should be confirmed based on the required temperature and process atmosphere, as the source does not specify exact compatibility limits beyond 1700°C.
Can the TF-1700-0L be used for both vacuum and flowing-gas processes, and what are the key configuration options for the gas/vacuum package?
Yes, the furnace supports controlled heating in vacuum or flowing-gas atmospheres. It features vacuum flanges, configurable heating zones, and a gas/vacuum package that must be specified to the technical sales team. The exact vacuum level and gas flow rates are not detailed in the product description and should be confirmed before quotation.
What configuration details must be confirmed before ordering the Atomfair TF-1700-0L tube furnace?
According to the product notice, the following must be confirmed before quotation: temperature class, usable process size (tube dimensions), gas/vacuum package, power supply, and accessory configuration. These parameters ensure the furnace meets the specific laboratory thermal processing requirements.
The Atomfair TF-1700-0L small sliding sample tube furnace provides 1700°C capability with uniform heating-field design, suitable for vacuum or flowing-gas thermal processing. Its configurable zones and quartz/ceramic tube arrangements allow tailored annealing and sintering, but the required pre-quotation confirmation of tube size, zone layout, and gas/vacuum package means buyers must specify exact process parameters.
Positive
- 1700°C high-temperature capability: The furnace can reach 1700°C, enabling high-temperature annealing, sintering, and thermal process development in a laboratory setting.
- Uniform heating-field with configurable zones: The design includes uniform heating-field and configurable heating zones, allowing precise temperature control across the sample area.
Trade-offs
- Custom configuration requires quotation confirmation: Temperature class, tube size, zone layout, gas/vacuum package, and power supply must be confirmed before ordering, meaning the furnace is not a standard off-the-shelf unit.
- Tube dimensions and sealing not predefined: The description does not specify exact tube dimensions or sealing method, requiring detailed specification input to match the user's process requirements.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).