Description
dPette+ Single-channel 20-200 µL PipetteProduct Type: Electronic pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The dPette+ Single-channel 20-200 µL Pipette requires careful sterilization handling as only the lower half is autoclavable. User calibration must be performed according to ISO 8655-2 at the specified test volumes to maintain accuracy.
- Sterilization Constraint: Only the lower half of the pipette may be autoclaved; the upper assembly must not be subjected to autoclaving.
- Calibration Requirement: User calibration must follow ISO 8655-2 reference at the test volumes of 200, 100, and 20 µL as listed in the technical specifications.
How does the accuracy of the dPette+ 20-200 µL pipette vary across its volume range, particularly at the lower end?
Accuracy decreases significantly at the lower end of the volume range. The systematic error is ±0.60% at 200 µL, ±1.00% at 100 µL, and ±4.00% at 20 µL, as specified in the technical table. This trade-off between volume range and precision must be considered for methods requiring high accuracy at low volumes.
What types of pipette tips are compatible with the dPette+ single-channel electronic pipette?
The product description does not specify a particular tip brand or type. It states to 'confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.' For specific tip compatibility, contact the Atomfair technical sales team.
Can the dPette+ 20-200 µL pipette be fully sterilized, and what are the sterilization limitations?
Only the lower half of the pipette is autoclavable. The technical specification explicitly lists 'Sterilization suitability: Lower half autoclavable.' This means the upper electronic components cannot be autoclaved, requiring alternative sterilization methods for those parts.
The dPette+ Single-channel 20-200 µL pipette offers a 1 µL increment and partial autoclavability, but the systematic error at 20 µL reaches ±4.00%, and calibration and tip compatibility must be confirmed for routine use.
Positive
- Autoclavable lower half for decontamination: The lower half of the pipette is autoclavable, allowing sterilization of the tip cone and lower assembly without damaging the upper electronic components.
- Traceable calibration data per test volume: Systematic and random error values are provided for each test volume (200, 100, 20 µL), enabling calibration verification against ISO 8655-2.
Trade-offs
- Partial autoclavability only: Only the lower half is autoclavable; the upper electronic components require separate cleaning procedures and cannot be sterilized by autoclaving.
- Elevated systematic error at 20 µL: At the minimum test volume of 20 µL, systematic error is ±0.80 µL (±4.00%), which may limit accuracy for precise low-volume transfers.