Quartz Spectroelectrochemical Cell 12×12mm ATOMFAIR®

$1,202.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

All-quartz spectroelectrochemical cell with 4 optical windows, ≥95% transmittance, 12×12mm body, PTFE lid, gas ports, and sealed Pt wire electrodes.

Small Sealed Quartz Spectroelectrochemical Cell | ATOMFAIR

Product Type: Electrochemical cell
Research-grade laboratory product

Product Overview

The ATOMFAIR® Small Sealed Quartz Spectroelectrochemical Cell features an all-quartz integrally ground body with four transparent optical windows for superior light transmission. The quartz exhibits a light transmittance exceeding 95%. The lid is manufactured from PTFE with an external threaded design for convenient operation. The cell is equipped with gas inlet and outlet ports. The cell includes a complete set of matched electrodes: both reference and counter electrodes are platinum wire, and the working electrode is a 3mm diameter glassy carbon electrode. The working electrode can be customized to 3mm gold disc, platinum disc, or other electrode materials upon request. The cell body is square with dimensions of 12×12mm and features an absolutely sealed system. The quartz sealing section employs an internal threaded design secured by tightening the PTFE cap. Absolute sealing of electrode connections is achieved via built-in jacks on the lid, enabling complete internal electrode integration.

Performance Features

  • All-quartz integrally ground construction: Four transparent optical windows with ≥95% light transmittance for superior spectroelectrochemical measurements.
  • Absolutely sealed design: Built-in electrode jacks on the lid provide complete sealing integrity for gas-sensitive and anaerobic experiments.
  • Complete electrode set included: Pt wire reference, Pt wire counter, and 3mm glassy carbon working electrode provided.
  • Flexible working electrode options: Can be customized to gold disc, platinum disc, or other 3mm electrodes upon request.
  • PTFE threaded lid: External thread design for convenient operation with reliable sealing.
  • Gas management capability: Inlet and outlet ports enable atmosphere control for gas-dependent experiments.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-C013-012-SLD
Cell Body Material All-quartz, integrally ground and polished
Optical Windows Four transparent windows
Light Transmittance ≥95%
Lid Material PTFE with external threaded design
Cell Body Dimensions 12×12mm (square)
Sealing Mechanism Internal threaded PTFE cap; built-in electrode jacks for absolute sealing
Gas Management Gas inlet and outlet ports included
Electrode Set Pt wire reference, Pt wire counter, 3mm glassy carbon working electrode
Working Electrode Options Glassy carbon (standard); 3mm gold disc, platinum disc, or others upon request
APPLICATION SCOPE: Spectroelectrochemistry, anaerobic UV-Vis electrochemical measurements, optically transparent electrode (OTE) studies, gas-sensitive electrochemical experiments, and electrochemical applications requiring optical access and absolute sealing in a compact cuvette format.
PACKAGING: Individual shock-proof packaging with specialized foam lining and reinforced cartons to ensure the quartz cell and electrodes remain intact during transportation.
IMPORTANT NOTICE: Handle quartz body with care to avoid scratches on optical windows. Ensure proper sealing before gas/vacuum operation. Avoid thermal shock. Verify electrode compatibility before use. Inspect seals before assembly.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This quartz spectroelectrochemical cell requires careful handling to prevent optical window damage and ensure gas-tight sealing. Proper electrode compatibility verification and thermal shock avoidance are critical for reliable operation.

  • Optical Window Care: Handle the quartz body with care to avoid scratches on the optical windows.
  • Sealing Integrity: Ensure proper sealing of the cell before initiating gas or vacuum operation.
  • Thermal Shock Avoidance: Avoid subjecting the quartz cell to rapid temperature changes to prevent thermal shock.
  • Electrode Compatibility: Verify that the electrodes are compatible with the intended electrochemical system before use.
  • Seal Inspection: Inspect all seals before assembly to confirm they are intact and clean.

What is the optical path length for UV-Vis measurements in the Small Sealed Quartz Spectroelectrochemical Cell?

The source does not specify an exact optical path length. The cell body is 12×12mm square with four transparent optical windows and ≥95% light transmittance. The effective path length depends on the internal geometry and beam alignment; for accurate quantification, calibration with known absorbance standards is recommended.

How is the absolute sealing of electrode connections maintained for anaerobic experiments in this spectroelectrochemical cell?

Absolute sealing is achieved via built-in electrode jacks on the PTFE lid that integrate the electrodes internally, combined with an internal threaded PTFE cap that secures the quartz sealing section. This design provides complete gas-tight integrity, making the cell suitable for gas-sensitive and anaerobic electrochemical measurements.

Can the working electrode be customized to alternative 3mm disc materials, and how can I request such customization?

Yes, the working electrode can be customized to 3mm gold disc, platinum disc, or other electrode materials upon request. The standard configuration includes a 3mm glassy carbon electrode. For customization requests or lead time, contact the technical sales team at inquiry@atomfair.com.

This small sealed quartz spectroelectrochemical cell offers an all-quartz integrally ground body with four windows and ≥95% transmittance, combined with a PTFE lid and gas ports for absolute sealing, making it suitable for anaerobic UV-Vis and gas-sensitive electrochemical measurements.

Positive

  • High transmittance quartz windows: All-quartz integrally ground body with four windows provides ≥95% light transmittance for superior optical access in spectroelectrochemical measurements.
  • Absolutely sealed design with gas ports: Built-in electrode jacks, PTFE threaded lid, and gas inlet/outlet ports enable complete sealing for anaerobic and gas-sensitive experiments, ensuring atmospheric control.

Trade-offs

  • Quartz fragility and handling care: The quartz body is susceptible to scratches on optical windows and thermal shock, requiring careful handling and avoidance of rapid temperature changes during operation.
  • Seal integrity and assembly requirement: Proper sealing must be verified before gas/vacuum use, and electrode compatibility must be confirmed; the internal threaded PTFE cap requires careful tightening to maintain absolute sealing.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Related Products