Cylindrical Quartz Electrochemical Cell, Open Type | ATOMFAIRProduct Type: Electrochemical cell
Research-grade laboratory product
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The quartz body requires careful handling to maintain optical clarity and structural integrity. Chemical compatibility with quartz must be verified before introducing any electrolyte or solvent.
- Scratch Prevention: Handle the quartz cell with care to avoid scratches on the optical windows, using the PTFE base to protect the bottom window during normal use.
- Thermal Shock Avoidance: Avoid subjecting the quartz cell to rapid temperature changes to prevent thermal shock and potential fracture.
- Chemical Compatibility Verification: Verify chemical compatibility of all intended electrolytes and solvents with quartz before use to prevent etching or degradation.
What is the optical transmittance of the quartz cell and how does the fusion-welded construction affect measurement accuracy?
The quartz cell exhibits ≥95% light transmittance, enabling high-quality spectroelectrochemical measurements. The all-quartz fusion-welded (non-bonded) construction ensures superior durability and optical clarity, minimizing signal loss or distortion from adhesive or bonded interfaces.
Which electrode configurations are compatible with this open cylindrical quartz electrochemical cell?
Recommended electrode configuration includes an Ag/AgCl reference electrode (3.8 mm diameter), a platinum wire counter electrode (0.5 mm diameter), and a 3 mm glassy carbon working electrode. Custom working electrodes such as gold disc or platinum disc are available upon request. Electrodes are not included and must be purchased separately.
How should the quartz cell be handled to prevent damage during use?
The cell includes a PTFE base that prevents scratching of the bottom quartz optical window during handling. To maintain optical clarity, avoid scratches on the windows and avoid thermal shock. Chemical compatibility with quartz should be verified before use to prevent etching or damage.
This open-type cylindrical quartz electrochemical cell provides high optical transparency (>95%) and durable all-quartz fusion welded construction, making it well-suited for spectroelectrochemical and photoelectrochemical studies. However, electrodes are not included and must be purchased separately, and the quartz body requires careful handling to avoid scratches and thermal shock.
Positive
- All-quartz fusion welded construction: Non-bonded design ensures superior durability and optical clarity, with light transmittance exceeding 95% for reliable spectroelectrochemical measurements.
- PTFE lid and protective base: Chemically inert and thermally stable PTFE lid provides reliable sealing, while the PTFE base prevents scratching of the bottom quartz optical window during handling and use.
Trade-offs
- Electrodes not included: Electrodes must be purchased separately; recommended configuration includes Ag/AgCl reference, platinum wire counter, and glassy carbon working electrode, requiring additional procurement coordination.
- Quartz handling and compatibility constraints: Quartz body requires careful handling to avoid scratches on optical windows and must be protected from thermal shock; chemical compatibility with quartz must be verified before use.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).






