Description
IoniSense pH DO 100 T Touch Screen Benchtop Electrochemistry MeterProduct Type: Touch Screen Benchtop Electrochemistry Meter
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The instrument requires a compatible electrode and probe configuration for the selected measurement parameter. Calibration must be performed using the provided standard solutions before use.
- Calibration Requirement: The instrument must be calibrated using 1-5 point automatic calibration with appropriate pH buffers and dissolved oxygen standards.
- Temperature Compensation: Automatic temperature compensation is active from -10.0°C to 135.0°C to maintain accuracy.
- Power Supply Constraint: The instrument operates exclusively on a DC12V power supply.
- Electrode Compatibility: Only electrodes and probes matched to the model configuration should be used.
- Data Output: Data can be exported via USB, PC, or printer connection for documentation.
This guide covers initial setup, electrode connection, and calibration before measurement. Ensure all standard solutions and accessories are available.
Required Equipment: pH electrode, Dissolved oxygen probe, Standard buffer solutions, Magnetic stirrer
- Power On
Connect the DC12V power adapter to the instrument and switch it on. - Connect Electrodes
Attach the pH electrode and dissolved oxygen probe to the designated ports. - Calibrate
Immerse the electrodes in the first standard solution and initiate automatic calibration. - Repeat Calibration
Repeat the calibration for each additional standard solution as required by the automatic calibration sequence. - Measure Sample
After calibration, place the electrodes into the sample solution for measurement.
How does the selectable pH resolution (0.1/0.01/0.001) affect the instrument's accuracy specification of ±0.002 pH?
The pH accuracy of ±0.002 pH ±1 digit is stated as a fixed specification independent of the selected resolution setting according to the product description. The resolution can be set to 0.1, 0.01, or 0.001 pH, but the accuracy tolerance remains ±0.002 pH regardless of the display resolution chosen.
What electrodes and probes are compatible with the IoniSense pH DO 100 T for performing ORP (mV) and dissolved oxygen measurements?
The standard package includes a pH electrode, conductivity electrode, and dissolved oxygen accessories, but the instrument's measurement parameters are pH/mV/°C, mV (ORP)/°C, and dissolved oxygen/°C. The product description requires users to confirm compatible electrode or probe configuration before quotation, indicating that specific electrode models are not listed in the documentation and must be verified with the supplier to match the intended parameter.
What are the power supply and environmental infrastructure requirements for operating the IoniSense pH DO 100 T benchtop meter?
The instrument requires a DC12V power supply, which is included in the standard package. It operates over a temperature compensation range of (-10.0 to 135.0) °C for measurement, but the product description does not specify ambient operating or storage temperature limits for the instrument itself. The package includes a magnetic stirrer, implying a stable benchtop surface with access to the supplied power adapter is needed.
This benchtop meter offers high-precision pH measurement (±0.002 pH) with automatic calibration up to 5 points and integrated dissolved oxygen sensing with temperature compensation across a wide range (-10 to 135°C), suitable for water quality and environmental analysis workflows.
Positive
- High-precision pH measurement: Achieves ±0.002 pH accuracy with selectable resolution down to 0.001 pH and up to 5-point automatic calibration for reliable quantification in demanding aqueous matrices.
- Integrated multi-parameter capability: Combines pH/mV/ORP and dissolved oxygen measurements in a single benchtop unit with automatic temperature compensation from -10 to 135°C, reducing instrument footprint for routine water quality screening.
Trade-offs
- Requires external DC power supply: Operates on DC12V input only; no battery option limits deployment to benchtop locations with mains power access.
- Accessory configuration must be confirmed: Standard package includes electrodes and probes according to model configuration; users must verify exact accessory set (pH electrode vs. DO probe) before ordering to avoid workflow gaps.