pH/Conductivity Pocket Tester 0-19.99 mS/cm ATOMFAIR®

$123.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade pocket tester measures -2.16 to 16.00 pH, 0-19.99 mS/cm and 0-60 °C with ±0.01 pH, ±1.0%F.S conductivity accuracy and ATC. Order now.

Description

IoniSense pH Conductivity 1 Plus Pocket Electrochemistry Tester

Product Type: Pocket Electrochemistry Tester
Research-grade laboratory product

Product Overview

Pocket Electrochemistry Tester IoniSense pH Conductivity 1 Plus Pocket Electrochemistry Tester supports pH / Conductivity across -2.16 to 16.00 pH; 0-19.99 mS/cm; 0-60 °C with pH ±0.01 ±1 digit; conductivity ±1.0%F.S ±1 digit and 0-60 °C on pocket meters; -10 to 135 °C on portable meters where applicable.

The instrument is intended for electrochemical measurement workflows such as water quality screening, environmental sampling, aquaculture, education, process checks and laboratory verification when those applications match the selected measurement parameter.

Calibration and temperature-compensation details are retained in the technical table so the selected model can be matched to the required parameter, range and workflow.

Performance Features

  • Measurement parameter: pH / Conductivity.
  • Measurement range: -2.16 to 16.00 pH; 0-19.99 mS/cm; 0-60 °C.
  • Accuracy: pH ±0.01 ±1 digit; conductivity ±1.0%F.S ±1 digit.
  • Calibration: Automatic calibration for supported parameters.
  • Temperature compensation: Automatic temperature compensation on supported models.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONSPHCONDUCTIVITY1PLUS
Measurement parameters pH / Conductivity
Accuracy pH ±0.01 ±1 digit; conductivity ±1.0%F.S ±1 digit
Measurement range -2.16 to 16.00 pH; 0-19.99 mS/cm; 0-60 °C
Temperature range 0-60 °C on pocket meters; -10 to 135 °C on portable meters where applicable
Calibration Automatic calibration for supported parameters
Temperature compensation Automatic temperature compensation on supported models
Package / accessories Electrode or probe, calibration solution, sample bottle, batteries, lanyard and carrying case according to model configuration

Selection and Use Notes

  • Confirm measurement parameter, range, accuracy, calibration requirement, temperature compensation and compatible electrode or probe before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This pocket electrochemistry tester requires automatic calibration before each use and operates within a 0-60 °C temperature range. Electrode compatibility and proper calibration solution selection must be confirmed to ensure measurement accuracy.

  • Calibration Requirement: The meter must be calibrated automatically using the supplied calibration solution before each measurement session to maintain specified accuracy.
  • Temperature Compensation Constraint: Automatic temperature compensation is only valid within the 0-60 °C operating range for this pocket meter model.
  • Electrode Compatibility: The electrode or probe must be matched to the measurement parameter and range to ensure reliable readings.
  • Accuracy Dependence: Achieving the stated pH ±0.01 and conductivity ±1.0% F.S accuracy requires the electrode to be properly maintained and the meter to be recently calibrated.

What is the maximum conductivity measurement range of the IoniSense pH Conductivity 1 Plus, and how does its temperature operating range compare to portable meters from the same series?

The maximum conductivity range is 0–19.99 mS/cm, suitable for freshwater and process checks. The pocket meter operates at 0–60 °C, while portable meters in the same series can measure from -10 to 135 °C, indicating a trade-off between pocket portability and wider temperature capability.

Does the automatic temperature compensation function cover both pH and conductivity measurements, and what calibration solutions are required?

The product features automatic temperature compensation for supported models, but the source does not explicitly state whether it applies to both pH and conductivity simultaneously. Calibration is automatic for supported parameters; the package includes calibration solution, but specific buffer or conductivity standard values are not specified. Confirm with the included accessories or contact technical sales.

What is the battery life of the IoniSense pH Conductivity 1 Plus, and how should the electrode be stored to maintain accuracy?

The product package includes batteries and a carrying case, but battery life is not specified in the provided description. Electrode storage instructions are not detailed; however, pH electrodes typically require wet storage. Users should consult the product manual for handling and storage recommendations.

The IoniSense pH Conductivity 1 Plus is a dual-parameter pocket meter offering pH and conductivity measurement with automatic calibration and temperature compensation, suitable for field and lab screening within 0–60 °C environmental range.

Positive

  • Combined pH and conductivity meter: Supports both pH (-2.16 to 16.00 pH) and conductivity (0–19.99 mS/cm) measurement in a single pocket device, reducing instrument count in field or routine lab workflows.
  • Automated calibration and compensation: Automatic calibration for supported parameters and automatic temperature compensation reduce operator intervention and improve repeatability across varying sample temperatures.

Trade-offs

  • Limited operating temperature range: The pocket meter variant operates only from 0–60 °C, restricting use for hot samples or high-temperature process monitoring where portable meters support up to 135 °C.
  • Conductivity accuracy adequate for screening: Conductivity accuracy is ±1.0% of full scale ±1 digit, which may be insufficient for applications requiring high-precision low-conductivity measurements near detection limits.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).