Mi-Pette Single-Channel Pipette 0.1-2.5 μL ATOMFAIR®

$58.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Mi-Pette single-channel manual pipette covers 0.1-2.5 μL in 0.002 μL increments, with ISO 8655-2 calibration reference and autoclavable use. Order now.

SKU: AF-EI-L-MIPT-A025-SC00
Category: ,
Tags:
Brands:

Description

Mi-Pette Single-channel 0.1-2.5 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette Single-channel 0.1-2.5 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.1-2.5 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 0.1-2.5 µL working range, 0.002 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 0.1-2.5 µL with 0.002 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-0-1-2-5-µL
Product Family Mi-Pette
Channel count Single-channel
Volume range 0.1-2.5 µL
Increment 0.002 µL
Test volume(s) 2.5 / 1.25 / 0.25 µL
Systematic error At 2.5 µL: ±0.06 µL (±2.5%); at 1.25 µL: ±0.06 µL (±5.0%); at 0.25 µL: ±0.06 µL (±25%)
Random error At 2.5 µL: ±0.05 µL (±2.0%); at 1.25 µL: ±0.05 µL (±4.0%); at 0.25 µL: ±0.05 µL (±20%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires calibration per ISO 8655-2 and supports high-temperature sterilization. Compatible tips must be selected to maintain specified accuracy and precision.

  • Calibration Requirement: Calibration according to ISO 8655-2 is required to ensure systematic error remains within ±0.06 µL at 2.5 µL and ±0.06 µL at 1.25 µL and 0.25 µL.
  • Sterilization Compatibility: High-temperature sterilization is supported but must be verified against the pipette's material compatibility.
  • Tip Compatibility: Compatible tips must be selected to achieve a stable tip fit and accurate volume delivery.
  • Workflow Verification: Laboratory workflow, including calibration and sterilization planning, should be confirmed before use.

How does the Mi-Pette 0.1-2.5 µL pipette's accuracy change when pipetting at the lower end of its volume range, specifically at 0.25 µL?

At the lower end of the range, the systematic error is ±0.06 µL (±25%) at 0.25 µL, compared to ±0.06 µL (±2.5%) at 2.5 µL. The random error is ±0.05 µL (±20%) at 0.25 µL versus ±0.05 µL (±2.0%) at 2.5 µL. This indicates significant relative accuracy degradation at volumes near the minimum, so users should account for this in method validation.

Can the Mi-Pette 0.1-2.5 µL pipette be fully autoclaved for sterilization between uses?

Yes, the Mi-Pette Single-channel 0.1-2.5 µL Pipette is described as a fully autoclavable manual pipette, supporting high-temperature sterilization where indicated by the source family. This allows sterilization between uses for applications requiring aseptic technique.

What calibration standard does the Mi-Pette 0.1-2.5 µL pipette follow and how is calibration verified?

The pipette is calibrated to ISO 8655-2 user calibration reference as indicated in the technical specifications. Systematic and random error values are provided for test volumes of 2.5, 1.25, and 0.25 µL, enabling users to verify calibration against these published tolerances. For method-specific volume matching and calibration planning, contact the Atomfair technical sales team.

The Mi-Pette Single-channel 0.1-2.5 µL pipette offers fine 0.002 µL increment control and full autoclavability for sterile microvolume work, but exhibits significant accuracy degradation at its lower volume limit of 0.25 µL with ±25% systematic error, necessitating careful volume selection and tip validation.

Positive

  • Fully autoclavable for sterile workflows: High-temperature sterilization is supported, enabling decontamination and reuse in PCR, qPCR, and aseptic applications without compromising structural integrity.
  • Fine 0.002 µL increment for precision: The 0.002 µL increment allows accurate volume adjustment within the 0.1–2.5 µL range, critical for low-volume reagent addition and serial dilution protocols requiring tight tolerances.

Trade-offs

  • High systematic error at lower volume limit: At 0.25 µL, systematic error reaches ±25% (±0.06 µL), requiring careful consideration for applications near the minimum volume where accuracy is critical.
  • Dependence on compatible tips and calibration: Optimal performance requires verifying tip compatibility, calibration schedule, and sterilization method prior to use; improper matching may compromise accuracy and reproducibility.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).