Mini Single-Channel 20 μL Fixed-Volume Pipette ATOMFAIR®

$2.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fixed-volume 20 μL single-channel mini pipette with ISO 8655-2 reference, ±0.12 μL systematic and ±0.10 μL random error. Order now.

SKU: AF-EI-L-MINP-H020-SC00
Category: ,
Tags:
Brands:

Description

Mini Pipette Single-channel 20 µL Pipette

Product Type: Fixed-volume mini pipette
Research-grade liquid handling platform

Product Overview

Mini Pipette Single-channel 20 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 20 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 20 µL working range, Fixed volume increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 20 µL with Fixed volume increment.
  • Sterilization suitability: Not suitable for high-temperature sterilization.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MINI-PIPETTE-20-µL
Product Family Mini Pipette
Channel count Single-channel
Volume range 20 µL
Increment Fixed volume
Test volume(s) 20 µL
Systematic error At 20 µL: ±0.12 µL (±0.6%)
Random error At 20 µL: ±0.10 µL (±0.5%)
Sterilization suitability Not suitable for high-temperature sterilization
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Fixed-volume pipette technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Calibration must be performed according to ISO 8655-2 to maintain accuracy. The pipette is not suitable for high-temperature sterilization, requiring alternative sterilization methods.

  • Calibration Requirement: Systematic and random error must be verified at the 20 µL test volume per ISO 8655-2 calibration reference.
  • Sterilization Constraint: High-temperature sterilization is not permitted; use only low-temperature chemical or UV sterilization methods.
  • Tip Compatibility: Compatible tips must be selected to ensure stable tip fit and accurate volume delivery.
  • Volume Accuracy: Fixed volume of 20 µL requires that the pipette is used only at that volume, with no adjustment possible.

How does the fixed-volume design of the 20 µL Mini Pipette affect accuracy compared to adjustable-volume pipettes for routine PCR setup?

The fixed-volume design eliminates volume-setting errors, ensuring consistent delivery at exactly 20 µL. Systematic error is ±0.12 µL (±0.6%) and random error is ±0.10 µL (±0.5%) at the test volume, as specified in the ISO 8655-2 calibration reference. This provides high repeatability for PCR and qPCR workflows, though it lacks the flexibility of adjustable models.

What tip compatibility and calibration requirements should be considered when integrating the 20 µL fixed-volume Mini Pipette into a qPCR workflow?

The pipette requires compatible 20 µL tips for proper sealing and accuracy; the source does not specify a particular brand, so tip compatibility should be confirmed with the supplier. It is calibrated per ISO 8655-2 at the factory, and user calibration is supported for routine performance checks. Note that the pipette is not suitable for high-temperature sterilization, so tips must be sterile if needed for qPCR.

What sterilization methods are compatible with the 20 µL Mini Pipette given that it is not suitable for high-temperature autoclaving?

The product specification explicitly states it is not suitable for high-temperature sterilization. Therefore, alternative decontamination methods such as chemical disinfection (e.g., 70% ethanol or isopropanol) or UV irradiation should be used. For aseptic applications, pre-sterilized tips and proper aseptic technique are recommended instead of autoclaving the pipette body.

The Atomfair Mini Pipette Single-channel 20 µL is a fixed-volume manual pipette offering ±0.12 µL systematic error and ±0.10 µL random error at 20 µL, with calibration traceable to ISO 8655-2. Its primary operational constraint is lack of high-temperature sterilization compatibility, requiring alternative decontamination methods, and the fixed volume limits application flexibility to single-volume workflows.

Positive

  • Fixed-volume precision at 20 µL: With systematic error of ±0.12 µL (±0.6%) and random error of ±0.10 µL (±0.5%) at 20 µL, this pipette delivers repeatable liquid transfer for applications such as PCR setup, serial dilution, and reagent addition.
  • ISO 8655-2 calibration reference: User calibration data is traceable to the ISO 8655-2 standard, facilitating routine performance verification and compliance with quality-control protocols in research and teaching laboratories.

Trade-offs

  • Not suitable for autoclaving: The pipette cannot be sterilized by high-temperature methods; users must rely on chemical decontamination or limited-use disposable barriers, which may increase consumable costs or require additional handling steps.
  • Fixed volume restricts flexibility: As a fixed-volume model at 20 µL, this pipette cannot be adjusted to other volumes, limiting its use to only those protocols that require exactly 20 µL transfers, necessitating additional pipettes for multi-volume workflows.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).