Operating constraints for the ATOMFAIR AF-MIXM microplate mixer are limited to stated ambient, electrical, and load limits. Use the unit only within 5-40 deg C, 80% RH, 100-240 V, 50/60 Hz, and a maximum 0.5 kg load including holder.
- Ambient operating limit: Operate only within 5-40 deg C and 80% RH.
- Electrical supply limit: Connect only to 100-240 V, 50/60 Hz mains supply.
- Maximum load: Do not exceed 0.5 kg total load including the holder.
- Speed configuration limit: Select speed according to the microplate configuration within the stated maximum ranges.
- Platform compatibility: Confirm adapter or platform compatibility and vessel format before operation.
This procedure covers setup and operation of the ATOMFAIR AF-MIXM microplate mixer within its stated safety limits. Confirm configuration and load before starting and operate only under specified ambient and electrical conditions.
Required Equipment: Atomfair AF-MIXM microplate mixer, Compatible microplate holder or platform
- Confirm compatibility
Confirm the selected model, adapter or platform, and vessel format before operation. - Verify environment
Verify that the ambient temperature and humidity are within 5-40 deg C and 80% RH. - Load microplate
Place the loaded microplate onto the platform without exceeding the 0.5 kg maximum load with holder. - Set speed
Set the speed within the single-microplate range of 0-1500 rpm or the double-microplate range of 0-1000 rpm. - Connect power
Connect the unit to a 100-240 V, 50/60 Hz mains supply. - Start and monitor
Start the mixer and monitor operation while it is running.
Why does the MixCore M microplate mixer have different maximum speeds for single versus double microplate operation?
The MixCore M is rated at 0-1500 rpm for single microplate operation and 0-1000 rpm for double microplate operation, both in circular mode with a 4.5 mm orbit diameter. When processing two stacked microplates, the maximum speed is reduced by 500 rpm. This speed-versus-configuration trade-off should be considered when planning high-throughput mixing workflows.
Which adapters, platforms, and vessel formats are compatible with the MixCore M microplate mixer?
Compatibility is configuration-dependent: the product documentation directs buyers to confirm adapter or platform compatibility, vessel format, and required quantity before quotation. The maximum load with holder is 0.5 kg, so the combined mass of the platform, holder, and loaded microplates must stay within that limit. Accessory matching and replacement parts are handled through technical sales based on the selected configuration.
What electrical supply and ambient conditions are required to operate the MixCore M microplate mixer?
The MixCore M operates on 100-240 V, 50/60 Hz, with a total power consumption of 20 W. Permissible ambient conditions are 5-40°C and 80% RH, and the unit carries IP21 protection. Laboratory installation should confirm that bench-level temperature, humidity, and electrical supply meet these specifications.
The MixCore M Microplate Mixer is a research-grade instrument with a brushless DC motor providing circular orbital mixing at 4.5 mm diameter, supporting single microplate speeds up to 1500 rpm and double microplate speeds up to 1000 rpm, with a maximum load of 0.5 kg. Its scale-based speed display and IP21 protection class indicate suitability for controlled benchtop environments where precise digital readout and high ingress protection are not required.
Positive
- Wide speed range for single microplate: The ability to operate from 0 to 1500 rpm on a single microplate allows for both gentle mixing and high-speed agitation, suitable for varied laboratory protocols.
- Brushless DC motor for durability: The 18 W input brushless DC motor provides consistent torque at 10 W output with reduced maintenance and longer operational lifespan compared to brushed alternatives.
Trade-offs
- Scale-based speed display limits precision: The speed display is a scale rather than a digital readout, which reduces the accuracy of setting and monitoring exact rpm values during sensitive assays.
- Load capacity restricts double microplate use: With a maximum load of 0.5 kg and double microplate speeds limited to 1000 rpm, the mixer may not be ideal for heavier or high-throughput stacking configurations without risk of reduced performance.