MicroPette Plus 8-Channel 50-300 μL Pipette ATOMFAIR®

$175.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable MicroPette Plus 8-channel pipette with 50-300 μL range, 5 μL increments and ISO 8655-2 calibration reference for QC labs. Order now.

SKU: AF-EI-L-MCPL-K300-08CH
Category: ,
Tags:
Brands:

Description

MicroPette Plus 8-channel 50-300 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

MicroPette Plus 8-channel 50-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 50-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 50-300 µL working range, 5 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 50-300 µL with 5 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MICROPETTE-PLUS-8CHANNEL-50-300-µL
Product Family MicroPette Plus
Channel count 8-channel
Volume range 50-300 µL
Increment 5 µL
Test volume(s) 300 / 150 / 50 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette requires regular calibration against ISO 8655-2 to maintain accuracy within specified systematic and random error limits. Full autoclavability permits sterilization but requires confirmation of cycle parameters to avoid damage.

  • Calibration Constraint: Calibrate according to ISO 8655-2 using the specified test volumes (50, 150, 300 µL) to ensure systematic and random error remain within defined limits.
  • Sterilization Constraint: Sterilize by autoclaving using a validated cycle; confirm temperature and duration from manufacturer documentation to prevent damage.
  • Tip Compatibility Constraint: Use only compatible tips designed for 8-channel 50-300 µL pipettes to maintain seal integrity and volumetric accuracy.
  • Error Tolerance Verification: Verify systematic and random error at each test volume against ISO 8655-2 limits to ensure compliance during routine use.

How does the 5 µL increment of the MicroPette Plus 8-channel pipette affect its suitability for applications requiring fine volume adjustments, such as serial dilutions?

The 5 µL increment allows for precise volume adjustments within the 50-300 µL range, making it suitable for serial dilutions and other applications requiring fine control. However, the systematic and random error values at the test volumes (300, 150, 50 µL) should be reviewed to ensure the required precision is met. The pipette is calibrated to ISO 8655-2, providing traceable error data for each test volume.

What type of pipette tips are compatible with the MicroPette Plus 8-channel 50-300 µL pipette, and how can one ensure proper tip fit?

The pipette requires 50-300 µL 8-channel tips. The product description advises confirming compatible tips, calibration requirements, and sterilization needs before ordering. The supplier, Atomfair, can provide specific tip recommendations to ensure proper sealing and prevent leakage. Users should avoid using tips that are not validated for this pipette model.

Is the MicroPette Plus 8-channel pipette fully autoclavable, and what are the implications for calibration after sterilization?

Yes, the pipette is fully autoclavable as indicated in the technical specifications. The product description does not specify exact autoclave cycles, so users should contact the Atomfair technical sales team for recommended parameters. After autoclaving, it is advisable to recalibrate the pipette per ISO 8655-2 to maintain accuracy, as thermal stress can affect the calibration.

The MicroPette Plus 8-channel 50-300 µL pipette offers fully autoclavable construction and ISO 8655-2 calibration reference, making it suitable for sterile microplate and PCR workflows requiring repeatable parallel liquid handling.

Positive

  • Fully autoclavable sterilization: The entire pipette can be autoclaved at 121°C, enabling decontamination between uses and reducing cross-contamination risk in sensitive assays.
  • 8-channel parallel processing: The 8-channel configuration allows simultaneous pipetting into microplates or PCR plates, increasing throughput for ELISA, sample preparation, and reagent transfer.

Trade-offs

  • Manual operation technique dependence: As a manual pipette, accuracy and precision depend on consistent user technique, requiring training and regular calibration verification.
  • 5 µL volume increment: The 5 µL increment limits fine volume adjustments; applications requiring steps smaller than 5 µL may need a different model.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).