Description
Mi-Pette Single-channel 10-100 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette requires compatible tips and periodic calibration per ISO 8655-2 to maintain specified accuracy. High-temperature sterilization is supported only for models indicated by the product family; cycle parameters must be confirmed with the manufacturer.
- Calibration Verification: Systematic and random error must be verified at the test volumes of 100, 50, and 10 µL to ensure the pipette operates within its specification.
- Tip Compatibility: Only use tips that are compatible with the 10-100 µL volume range and securely fit the pipette shaft to prevent leakage or inaccuracy.
- Sterilization Procedure: For models that support high-temperature sterilization, autoclave only the designated components and allow complete cooling before reassembly and use.
How does the accuracy of the Mi-Pette 10-100 µL pipette change when measuring near the lower end of its volume range?
At the lower test volume of 10 µL, the systematic error is ±0.8 µL (±8.0%), compared to ±0.8 µL (±0.8%) at 100 µL and ±0.8 µL (±1.6%) at 50 µL. The random error at 10 µL is ±0.3 µL (±3.0%), versus ±0.3 µL (±0.3%) at 100 µL. This tenfold increase in relative error means users should calibrate frequently or select a smaller-range pipette for high-accuracy work at volumes near 10 µL.
What tip compatibility and sterilization constraints apply to the Mi-Pette 10-100 µL pipette?
The pipette requires compatible tips for the 10-100 µL volume range, though specific tip models are not listed in the source. It is described as a fully autoclavable manual pipette, meaning high-temperature sterilization is supported; however, the technical specification table notes sterilization suitability is indicated by the source family, so users should confirm with the manufacturer for their specific unit. The single-channel configuration is suitable for PCR, qPCR, serial dilution, and routine analytical transfer, but not for multi-channel applications.
What calibration and maintenance procedures are required for the Mi-Pette 10-100 µL pipette to maintain ISO 8655-2 compliance?
The pipette is calibrated per ISO 8655-2, with systematic and random error values provided at test volumes of 100, 50, and 10 µL for performance review. Regular calibration verification is recommended, especially when operating near the 10 µL lower limit where relative error is highest. The pipette supports high-temperature sterilization, but users should follow the manufacturer's guidelines for autoclavability and calibration intervals to maintain traceable accuracy.
The Mi-Pette Single-channel 10-100 µL Pipette is a fully autoclavable manual pipette offering a 0.1 µL increment and ISO 8655-2 calibration reference, with systematic error ranging from ±0.8% at 100 µL to ±8.0% at 10 µL, making it suitable for routine liquid transfer and PCR setup but requiring careful volume matching for high-accuracy applications at the lower end of its range.
Positive
- Fully autoclavable for sterilization: The pipette supports high-temperature sterilization, enabling decontamination between uses in teaching, quality-control, and research labs without disassembly.
- ISO 8655-2 calibration reference: Calibration data per ISO 8655-2 is provided for test volumes of 100, 50, and 10 µL, allowing traceable performance verification and method setup.
Trade-offs
- High systematic error at low volume: At 10 µL, systematic error reaches ±8.0% (±0.8 µL), which may limit accuracy for applications requiring precise low-volume dispensing without recalibration.
- Requires compatible tip confirmation: The user must confirm compatible tips before ordering, as tip fit directly affects repeatability and calibration validity across the 10-100 µL range.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).