Mi-Pette 12-Channel Manual Pipette 30-300 μL ATOMFAIR®

$237.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable Mi-Pette 12-channel manual pipette with 30-300 µL range, 0.2 µL increment and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-MIPT-J300-12CH
Category: ,
Tags:
Brands:

Description

Mi-Pette 12-channel 30-300 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette 12-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 30-300 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 30-300 µL with 0.2 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-12CHANNEL-30-300-µL
Product Family Mi-Pette
Channel count 12-channel
Volume range 30-300 µL
Increment 0.2 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error At 300 µL: ±4.8 µL (±1.6%); at 150 µL: ±4.8 µL (±3.2%); at 30 µL: ±4.8 µL (±16%)
Random error At 300 µL: ±1.8 µL (±0.6%); at 150 µL: ±1.8 µL (±1.2%); at 30 µL: ±1.8 µL (±6.0%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic calibration per ISO 8655-2 using the specified test volumes of 300, 150, and 30 µL. High-temperature sterilization is permitted only when indicated by the product family; tip compatibility must be verified to ensure proper seal and accuracy.

  • Calibration Procedure: Perform calibration at the three test volumes to verify systematic and random error remain within the listed specifications.
  • Sterilization Limitation: Confirm that the specific pipette variant supports high-temperature autoclaving before initiating any sterilization cycle.
  • Tip Compatibility: Select tips designed for 12-channel pipettes in the 30-300 µL range to avoid leakage or volume inaccuracy.

How does the systematic error of the Mi-Pette 12-channel 30-300 µL pipette vary across its volume range, and what are the implications for low-volume assay accuracy?

The systematic error is constant at ±4.8 µL for all test volumes (300, 150, and 30 µL), but as a percentage it increases from ±1.6% at 300 µL to ±16% at 30 µL. This means that at the low end of the range, the relative error becomes significant, and users should verify whether the ±16% systematic error at 30 µL meets their assay precision requirements before deploying the pipette for low-volume workflows.

What calibration standard is used for the Mi-Pette 12-channel pipette, and does it require specific tip types or calibration tools for ISO 8655-2 compliance?

The pipette is calibrated per ISO 8655-2 as indicated in the technical table. The product description confirms that compatible tips must be verified before ordering, but does not mandate a specific tip brand. For ISO 8655-2 compliance, gravimetric calibration with the recommended tip type and a suitable analytical balance is required, and the user should confirm tip compatibility with the supplier.

Can the Mi-Pette 12-channel 30-300 µL pipette be fully sterilized by autoclaving, and are there any limitations on repeated high-temperature cycles?

Yes, the product overview states it is fully autoclavable, and the technical specification confirms high-temperature sterilization is supported where indicated by the source family. However, repeated autoclaving may affect calibration and tip fit over time; routine calibration checks after sterilization cycles are recommended to maintain the specified systematic and random error values.

The Mi-Pette 12-channel 30-300 µL pipette is a manual multichannel pipette suitable for parallel liquid handling in microplate and PCR applications, with high-temperature sterilization support. However, its systematic error is disproportionately high at the lower end of the volume range, requiring careful volume selection for accurate low-volume transfers.

Positive

  • 12-channel parallel liquid handling: The 12-channel configuration enables simultaneous microplate loading, PCR preparation, and ELISA workflows, increasing throughput for repeated reagent transfers.
  • High-temperature sterilization compatibility: The pipette supports high-temperature sterilization where indicated by the product family, allowing decontamination between uses in biohazard or sterile workflows.

Trade-offs

  • Elevated systematic error at low volume: At 30 µL, systematic error reaches ±4.8 µL (±16%), significantly reducing accuracy for small-volume transfers compared to higher volumes.
  • Requires tip and calibration verification: Compatible tips and calibration must be confirmed before workflow integration, adding an upfront validation step for new installations.