SpinCore M 0306 Low-Speed Centrifuge, 3400 rpmProduct Type: Low-Speed Centrifuge
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This document outlines critical operational constraints for the SpinCore M 0306 low-speed centrifuge to ensure safe and reliable performance. Adherence to these constraints prevents mechanical failure, electrical hazard, and sample loss.
- Rotor and Tube Compatibility: Use only tubes within the specified volume range and compatible rotor adapters to avoid tube rupture and imbalance.
- Speed and RCF Limits: Do not exceed the maximum speed and centrifugal force ratings to prevent rotor overspeed and potential catastrophic failure.
- Balanced Loading: Always balance tubes by weight and load symmetrically to minimize vibration and noise, and to protect the motor and drive system.
- Electrical Safety: Connect the centrifuge to a properly grounded power outlet and do not use damaged cords or plugs to reduce electrical shock risk.
- Operation Monitoring: Monitor the centrifuge for abnormal noise, vibration, or odor during operation and stop immediately if any occur.
Follow these steps to initialize and safely run a centrifugation cycle. Proper preparation and monitoring ensure sample integrity and equipment longevity.
- Confirm Compatibility
Confirm the rotor, adapter, and tube compatibility with the selected centrifuge model before loading samples. - Verify Parameters
Verify the required speed and RCF parameters against the sample protocol. - Match Tube Format
Ensure the sample-container format (tube size and volume) matches the rotor capacity specifications.
What is the maximum RCF of the SpinCore M 0306 centrifuge at 3400 rpm, and how does it affect sample separation efficiency?
The maximum RCF is 1600 × g at 3400 rpm. This relatively low relative centrifugal force is suitable for gentle pelleting of large particles or cell separations where high g-force could damage fragile samples, but it may not be adequate for subcellular organelle or nanoparticle pelleting. The acceleration time under 10 seconds and deceleration under 20 seconds help maintain consistent run-to-run separation profiles.
Can the SpinCore M 0306 centrifuge accommodate 10 mL conical tubes directly, or are adapters required?
The rotor capacity is listed as 6 x 3-10 mL tubes, indicating that both 3 mL and 10 mL tube formats are supported, but adapter compatibility must be confirmed before use. The product notes explicitly state to confirm rotor, adapter and tube compatibility before quotation, so while the swing-out rotor likely accepts standard 10 mL conical tubes, specific adapter requirements depend on tube geometry and material.
What are the power and noise level requirements for installing the SpinCore M 0306 in a shared laboratory space?
The centrifuge operates on 80 W power and produces a noise level of ≤63 dB. This low power draw allows standard wall outlet connection without dedicated circuits, and the noise level is comparable to a quiet conversation, making it suitable for open-plan labs or shared rooms. The compact dimensions of 359 x 318 x 222 mm and weight of 5.3 kg also simplify benchtop placement without reinforced flooring.
This low-speed centrifuge offers fixed-speed operation at 3400 rpm with a maximum RCF of 1600 × g and a rotor capacity of six tubes (3–10 mL), suitable for routine separation tasks requiring moderate g-force but limited by ambient-only operation and low maximum RCF.
Positive
- Fixed-speed operation at 3400 rpm: The fixed speed of 3400 rpm supports method-specific centrifugation protocols without variability.
- Flexible rotor capacity for small tubes: Rotor accommodates six tubes ranging from 3 to 10 mL, enabling direct tube matching for common sample volumes.
Trade-offs
- Low maximum RCF limits applications: With a maximum RCF of only 1600 × g, this centrifuge is restricted to low-speed separations and cannot support protocols requiring higher g-force.
- No temperature control provided: The unit operates at ambient temperature only; no refrigeration or heating is available for heat-sensitive samples.