IoniSense Conductivity DO 10 Portable Electrochemistry MeterProduct Type: Portable Electrochemistry Meter
Research-grade laboratory product
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The meter requires automatic calibration with supported standards and automatic temperature compensation. Electrode or probe must be selected for the specific measurement parameter and range.
- Calibration Requirement: Calibration must be performed with standard solutions appropriate for Conductivity and Dissolved oxygen parameters.
- Electrode Compatibility: The electrode or probe must be compatible with the selected measurement parameter and configured for automatic temperature compensation.
How does the ±0.5% F.S. ±1 digit conductivity accuracy specification affect measurement precision at low conductivity values on the IoniSense Conductivity DO 10 meter?
The conductivity accuracy is ±0.5% of full scale (2000 mS/cm) ±1 digit, so the absolute error remains constant at ±10 mS/cm ±1 digit across the entire 0–2000 mS/cm range. At low conductivity values (e.g., 0–100 mS/cm), this fixed absolute error results in a high relative error, reducing precision for low-conductivity applications. The source does not provide a separate accuracy specification for sub-ranges, so users should verify whether the meter’s full-scale-based error meets their required precision at the expected measurement level.
What are the intended applications for the IoniSense Conductivity DO 10 meter, and are there any known limitations for dissolved oxygen measurements in high-salinity environments?
The meter is intended for water quality screening, environmental sampling, aquaculture, education, process checks, and laboratory verification. The dissolved oxygen measurement range is 0–20.00 mg/L with ±0.30 mg/L accuracy. The source does not specify salinity compensation or limitations for high-salinity matrices, but the inclusion of automatic calibration and temperature compensation, along with the stated application in aquaculture, suggests the meter can be used in brackish or saltwater environments. Users should confirm compatibility with their specific sample salinity and dissolved oxygen range.
What accessories and consumables are included with the IoniSense Conductivity DO 10 meter to support immediate field deployment?
The meter is supplied with an electrode or probe, calibration solution, sample bottle, batteries, lanyard, and carrying case according to the model configuration. These accessories enable immediate field use without additional procurement. The carrying case provides protection during transport and storage; the source does not specify battery life or storage conditions, so users should refer to the included documentation for detailed handling instructions.
The IoniSense Conductivity DO 10 Portable Electrochemistry Meter integrates conductivity and dissolved oxygen measurement in a single portable unit, offering automatic calibration and temperature compensation for field and laboratory water quality analysis. Its broad measurement ranges (0–2000 mS/cm, 0–20.00 mg/L, –10 to 135 °C) enable versatile deployment, though users must confirm accuracy specifications and probe compatibility against their specific workflow requirements.
Positive
- Dual-parameter measurement capability: Single portable meter measures both conductivity and dissolved oxygen, reducing instrument count and simplifying multi-parameter water quality screening in environmental, aquaculture, and educational settings.
- Extended temperature range on portable models: The portable meter variant supports –10 to 135 °C, enabling operation across cryogenic and high-temperature process streams, unlike pocket-meter versions limited to 0–60 °C.
Trade-offs
- Moderate dissolved oxygen accuracy: DO accuracy is specified as ±0.30 mg/L, which is typical for portable meters but may not meet the tighter tolerances required for certain high-precision laboratory or regulatory dissolved oxygen measurements.
- Calibration and probe dependency: Automatic calibration and temperature compensation are supported only for compatible parameters and probes; users must select the correct electrode and calibration solution for their specific analyte, adding procurement verification steps.