Description
IoniSense Conductivity 100 Benchtop Electrochemistry MeterProduct Type: Benchtop Electrochemistry Meter
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The IoniSense Conductivity 100 meter requires careful electrode selection and periodic calibration for accurate conductivity, TDS, salinity, and resistivity measurements. Temperature compensation is limited to 0-50°C, and the instrument must be powered by a stable DC12V supply.
- Calibration Requirement: The instrument requires periodic single-point calibration using conductivity standard solutions to maintain specified accuracy of ±1.0% FS.
- Electrode Compatibility: Confirm that the selected electrode covers the required conductivity range and is compatible with the instrument's automatic range segmentation.
- Temperature Compensation Range: Temperature compensation is active only within 0.0-50.0 °C, and measurements outside this range will not be temperature-corrected.
- Power Supply Requirement: The instrument operates on DC12V power; ensure a stable power supply within the specified voltage to prevent measurement drift.
- Data Output Connectivity: Data output via USB, PC, or printer requires compatible cables and software; verify connectivity before use.
How does the automatic segmentation of the conductivity measurement range affect the accuracy and resolution of the IoniSense Conductivity 100 across different sample types?
The meter automatically segments the full 0–200 mS/cm range into five sub-ranges (0–19.99 µS/cm, 20.0–199.9 µS/cm, 200–1999 µS/cm, 2.00–19.99 mS/cm, and 20.00–199.9 mS/cm), providing optimized resolution of 0.001 in the lowest sub-range. However, the overall accuracy is ±1.0% FS ±1 digit, meaning the absolute error scales with the full-scale value—so high-conductivity samples have a larger potential error while low-conductivity samples benefit from finer resolution.
What are the limitations of the temperature compensation function on the IoniSense Conductivity 100 when measuring samples outside the 0–50 °C range?
The conductivity temperature compensation is only active between 0.0 °C and 50.0 °C, even though the meter can measure temperature from –9.9 °C to 130.0 °C. Samples measured outside the compensation range will not be automatically corrected for temperature, so users must either manually apply a reference temperature correction or rely on uncompensated conductivity readings, which can introduce significant error if the sample temperature deviates from the calibration temperature.
What infrastructure and consumables are required to operate the IoniSense Conductivity 100 benchtop meter out of the box?
The standard package includes the instrument, either the IoniProbe Conductivity 201 TG or 201 T electrode, conductivity standard solutions, universal electrode holder, magnetic stirrer, and a DC12V power adapter. Data output is available via USB, PC, or printer. No additional infrastructure is needed for basic operation, but the electrode must be stored properly in a suitable solution and the conductivity standards must be used within their shelf life to maintain calibration accuracy.
The IoniSense Conductivity 100 is a benchtop meter offering conductivity, TDS, salinity, resistivity, and temperature measurement with automatic range segmentation from 0-200 mS/cm. Its single-point calibration and limited temperature compensation range (0-50°C) are key operational constraints.
Positive
- Wide conductivity range with automatic segmentation: Covers 0-200 mS/cm across five automatic sub-ranges, enabling precise measurement from low to high conductivity samples without manual range switching.
- Multi-parameter measurement capability: Simultaneously supports conductivity, TDS, salinity, resistivity, and temperature, consolidating several routine water quality checks into one instrument.
Trade-offs
- Single-point calibration only: With only one calibration point, accuracy across the full 200 mS/cm range may be degraded, requiring careful selection of calibration standard for the expected measurement range.
- Limited temperature compensation range: Temperature compensation is specified only for 0.0-50.0 °C, restricting reliable use to samples within that thermal window and potentially introducing error outside it.