Low-Conductivity Electrode K=0.01 0–2 μS/cm ATOMFAIR®

$113.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Titanium alloy low-conductivity electrode with G3/4, K=0.01, 0–2 μS/cm range, 16 mm × 50 mm body, 4-core interface and 1 m cable. Order now.

Description

IoniProbe Conductivity 0.01 VK Low-conductivity electrode

Product Type: Electrochemistry Electrode
Research-grade laboratory product

Product Overview

Electrochemistry Electrode IoniProbe Conductivity 0.01 VK Low-conductivity electrode supports Low-conductivity electrode with G3/4, K=0.01, 0-2 uS/cm and Diameter 16 mm x 50 mm in a Titanium alloy body.

It is configured for electrochemistry meter workflows where electrode model, measurement medium, connector, reference solution and application fit must be checked before purchase.

Application: Ultra-pure water, medicine, power plant. Interface: 4-core.

Performance Features

  • Electrode or accessory type: Low-conductivity electrode.
  • Measurement range: G3/4, K=0.01, 0-2 uS/cm.
  • Temperature compensation: 10K where listed in the product configuration; otherwise not included.
  • Interface: 4-core.
  • Electrode body: Titanium alloy.
  • Reference solution: Not applicable.
  • Application fit: Ultra-pure water, medicine, power plant.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONPCONDUCTIVITY001VK
Electrode model IoniProbe Conductivity 0.01 VK
Name Low-conductivity electrode
Electrode body Titanium alloy
Cable length 1 m unless specified otherwise
Internal temperature compensation 10K where listed in the product configuration; otherwise not included
Interface 4-core
Reference solution Not applicable
Specification Diameter 16 mm x 50 mm
Measurement range G3/4, K=0.01, 0-2 uS/cm
Application Ultra-pure water, medicine, power plant

Selection and Use Notes

  • Confirm electrode model, connector, body material, cable length, reference solution and sample medium compatibility before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This low-conductivity electrode requires precise compatibility verification before use. Electrode model, connector type, body material, cable length, reference solution, and sample medium must all match the intended application.

  • Measurement Range Constraint: The electrode is specified for G3/4, K=0.01, 0 to 2 uS/cm measurement range and must not be used outside this range.
  • Connector Interface Constraint: The electrode uses a 4-core interface that must match the meter's connector.
  • Application Fit Constraint: The electrode is designed for ultra-pure water, medicine, and power plant applications and may not be suitable for other media.
  • Body Material Constraint: The titanium alloy body is compatible with the specified applications but may be incompatible with corrosive chemicals.
  • Temperature Compensation Constraint: Temperature compensation is only available when the product configuration includes a 10K thermistor; otherwise not included.

Why choose a K=0.01 conductivity electrode over a standard K=1.0 electrode for ultra-pure water measurements?

The K=0.01 electrode is specifically designed for the 0–2 µS/cm range used in ultra-pure water, providing higher sensitivity and accuracy at these low levels compared to standard K=1.0 electrodes, which are optimized for higher conductivity (typically 1–200 µS/cm). However, its narrow measurement range makes it unsuitable for samples above 2 µS/cm, limiting its use to ultra-pure water, medicine, and power plant applications as specified.

Can the IoniProbe Conductivity 0.01 VK electrode be connected to any conductivity meter?

No, the electrode requires a meter with a 4-core interface and a G3/4 threaded connection as specified. The titanium alloy body is chosen for corrosion resistance in demanding applications like ultra-pure water, medicine, and power plants, so compatibility with the meter’s input and the intended measurement medium must be confirmed before purchase.

What special handling or storage conditions are required for this low-conductivity electrode to maintain accuracy in ultra-pure water measurements?

To avoid contamination in the 0–2 µS/cm range, the electrode must be stored clean and dry, handled with gloves to prevent oil transfer from skin. The standard configuration does not include internal temperature compensation (10K TC is listed only where specifically configured), so a separate temperature probe or meter with external compensation is needed for accurate measurements in ultra-pure water.

The IoniProbe Conductivity 0.01 VK low-conductivity electrode, with a titanium alloy body and 0-2 µS/cm range, is optimized for ultra-pure water and pharmaceutical applications. Its G3/4 interface and 4-core connector require careful configuration validation, particularly regarding the availability of internal temperature compensation.

Positive

  • Titanium alloy body for durability: The titanium alloy electrode body provides excellent corrosion resistance and mechanical robustness, making it suitable for demanding low-conductivity measurement environments such as power plant water systems.
  • Optimized for ultra-pure water: With a cell constant K=0.01 and measurement range of 0-2 µS/cm, this electrode is specifically designed for high-precision conductivity measurement in ultra-pure water, pharmaceutical, and power plant applications.

Trade-offs

  • Temperature compensation not guaranteed: Internal temperature compensation (10K) is only included when explicitly listed in the product configuration; if absent, the user must supply external temperature measurement for accurate conductivity readings.
  • Limited to low-conductivity samples: The measurement range is restricted to 0-2 µS/cm, which confines this electrode exclusively to low-conductivity applications and precludes use in general-purpose or higher-conductivity measurement scenarios.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).