Description
IoniProbe Conductivity 2010 Conductivity electrodeProduct Type: Electrochemistry Electrode
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This conductivity electrode requires careful compatibility verification before use. Matching electrode model, connector type, body material, cable length, and sample medium is essential for accurate measurement and electrode longevity.
- Electrode Model Compatibility: The electrode model must match the intended conductivity meter to ensure proper calibration and signal processing.
- Connector Type: A BNC interface is required; verify that the meter provides a compatible BNC input.
- Body Material: The glass body is suitable for most aqueous solutions but may be incompatible with hydrofluoric acid or strong alkalis; verify chemical resistance.
- Cable Length: Cable length is 1 meter unless otherwise specified; ensure sufficient length for the measurement setup without straining the connection.
- Application Range: This electrode is designed for high-conductivity solutions (1-2000 mS/cm); using it outside this range may yield inaccurate readings.
Follow these steps to confirm the electrode is suitable for your application before procurement. Proper matching prevents measurement errors and equipment damage.
Required Equipment: Conductivity meter with BNC interface, Product specification sheet, Chemical compatibility reference
- Confirm Electrode Model
Verify that the electrode model (IoniProbe Conductivity 2010) matches the intended conductivity meter's supported electrode list. - Check Connector and Body Material
Inspect the BNC connector and glass body for compatibility with the meter's input and the sample's chemical properties. - Assess Application Range
Confirm that the sample conductivity falls within the electrode's measurement range of 1-2000 mS/cm. - Verify Cable Length
Measure the distance from the meter to the measurement point and ensure the 1-meter cable is sufficient. - Review Documentation
Cross-reference the product specifications with the laboratory's procurement and usage requirements before finalizing the order.
Why is a cell constant of k=10 specified for the IoniProbe Conductivity 2010, and what are the consequences for measuring low-conductivity samples?
The k=10 cell constant is specifically designed for the 1–2000 mS/cm high-conductivity range, minimizing polarization errors at high ionic strengths. For samples below 1 mS/cm, measurement accuracy and sensitivity will be significantly reduced because the electrode geometry is optimized for high conductivity, as indicated by the specified application fit.
Is the IoniProbe Conductivity 2010 compatible with existing laboratory conductivity meters via its BNC interface?
Yes, the IoniProbe Conductivity 2010 utilizes a standard BNC connector, which is compatible with most conductivity meters that accept BNC inputs. However, users must also ensure that the meter can accommodate a k=10 cell constant and, if temperature compensation is required, that the 10K thermistor (when configured) is supported by the meter's firmware or settings.
What handling considerations arise from the glass-body construction and 1 m cable length of the IoniProbe Conductivity 2010?
The glass body (12 mm × 120 mm) is durable in chemical environments but mechanically fragile, requiring careful handling to avoid breakage. The standard 1 m cable length may restrict placement relative to the meter; longer cables can be requested if specified in the configuration. No reference solution is needed, simplifying maintenance.
This IoniProbe Conductivity 2010 electrode (k=10) is engineered for high-conductivity measurements up to 2000 mS/cm, featuring a glass body and BNC interface. Temperature compensation is optional and must be confirmed during ordering.
Positive
- Wide high-conductivity range: With a cell constant of k=10, this electrode measures conductivity from 1 to 2000 mS/cm, enabling accurate readings in concentrated electrolytes and industrial process waters.
- Chemically resistant glass body: The glass body provides broad chemical compatibility and dimensional stability, making it suitable for aggressive high-conductivity solutions.
Trade-offs
- Lacks default temperature compensation: Internal temperature compensation (10K) is only included when explicitly configured; otherwise, users must supply external compensation, adding complexity to thermally corrected measurements.
- Limited to high-conductivity applications: This electrode is designed solely for high-conductivity solutions and is not suitable for low-conductivity or ultrapure water measurements.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).





