Single-Channel Pipette 5-50 μL 0.05 μL HiPette ATOMFAIR®

$88.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette single-channel pipette, 5-50 μL range with 0.05 μL increments and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HIPP-E050-SC00
Category: ,
Tags:
Brands:

Description

HiPette Single-channel 5-50 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette Single-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-5-50-µL
Product Family HiPette
Channel count Single-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error At 50 µL: ±0.45 µL (±0.9%); at 25 µL: ±0.35 µL (±1.4%); at 5 µL: ±0.15 µL (±3.0%)
Random error At 50 µL: ±0.15 µL (±0.3%); at 25 µL: ±0.20 µL (±0.8%); at 5 µL: ±0.08 µL (±1.6%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette must be calibrated according to ISO 8655-2 to ensure accuracy within specified systematic and random error limits. Autoclavable sterilization at 121°C is permitted but may require recalibration after repeated cycles.

  • Calibration Reference: Calibration must be performed against ISO 8655-2 user calibration reference at test volumes 50, 25, and 5 µL.
  • Sterilization Compatibility: The pipette is fully autoclavable, but repeated autoclaving may affect calibration accuracy.
  • Tip Compatibility: Compatible tips must be used to ensure stable tip fit and avoid leakage or volume errors.

How does the systematic error of the HiPette 5-50 µL pipette vary across its volume range, and what are the implications for low-volume assays?

The systematic error at 50 µL is ±0.45 µL (±0.9%), at 25 µL is ±0.35 µL (±1.4%), and at 5 µL is ±0.15 µL (±3.0%). The relative error increases significantly at lower volumes, which may affect precision in applications requiring accurate dispensing at 5 µL, such as PCR setup or serial dilution endpoints.

What sterilization procedures are compatible with the HiPette 5-50 µL pipette, and are special tip types required for optimal performance?

The pipette is fully autoclavable, allowing complete sterilization without disassembly. The description indicates compatible tips are required but does not specify a particular brand or type; users should confirm tip compatibility based on their workflow and ensure tips are designed for the 5-50 µL range to maintain accuracy.

What calibration standard does the HiPette 5-50 µL adhere to, and how should calibration be verified in a routine laboratory setting?

The pipette references ISO 8655-2 user calibration, with systematic and random error values provided for test volumes of 50, 25, and 5 µL. Routine verification can be performed by gravimetric testing at these volumes against the stated error limits, following the ISO 8655-2 procedure.

The HiPette Single-channel 5-50 µL pipette offers a fully autoclavable design with documented systematic and random error at three test volumes, suited for routine liquid handling in research and teaching labs. Its operational constraints include the need for compatible tips and periodic calibration.

Positive

  • Fully autoclavable for complete sterilization: The entire pipette can be autoclaved, enabling decontamination between uses in aseptic workflows such as PCR setup and cell culture.
  • Documented accuracy and precision across test volumes: Systematic error and random error are specified at 50 µL, 25 µL, and 5 µL, allowing users to assess method suitability and calibrate per ISO 8655-2.

Trade-offs

  • Requires compatible tip selection: Correct tip fit is essential for volumetric accuracy; users must confirm tip compatibility with the pipette model before use.
  • Calibration and maintenance required: Periodic calibration per ISO 8655-2 is necessary to maintain specified accuracy; routine user calibration reference is provided but requires proper equipment.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).