HiPette 0.5-10 μL Fully Autoclavable Pipette ATOMFAIR®

$88.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette single-channel pipette with 0.5-10 μL range, 0.01 μL increment, and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HIPP-B010-SC00
Category: ,
Tags:
Brands:

Description

HiPette Single-channel 0.5-10 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette Single-channel 0.5-10 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.5-10 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 0.5-10 µL working range, 0.01 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 0.5-10 µL with 0.01 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-0-5-10-µL
Product Family HiPette
Channel count Single-channel
Volume range 0.5-10 µL
Increment 0.01 µL
Test volume(s) 10 / 5 / 1 µL
Systematic error At 10 µL: ±0.10 µL (±1.0%); at 5 µL: ±0.08 µL (±1.5%); at 1 µL: ±0.03 µL (±2.5%)
Random error At 10 µL: ±0.04 µL (±0.4%); at 5 µL: ±0.04 µL (±0.8%); at 1 µL: ±0.02 µL (±1.8%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette is fully autoclavable for sterilization but requires careful calibration maintenance. Compatible tips and ISO 8655-2 calibration are essential for accurate performance.

  • Sterilization Constraint: Repeated autoclaving cycles may degrade sealing components and affect calibration accuracy.
  • Calibration Requirement: Calibration must be performed according to ISO 8655-2 using the stated test volumes to maintain specified systematic and random error limits.
  • Tip Compatibility: Only tips designed for 0.5-10 µL volumes and single-channel pipettes should be used to ensure proper fit and accuracy.

How does the systematic error of the HiPette 0.5-10 µL pipette change across its volume range, and what does that mean for low-volume accuracy?

Systematic error increases in percentage terms at lower volumes: ±0.10 µL (±1.0%) at 10 µL, ±0.08 µL (±1.5%) at 5 µL, and ±0.03 µL (±2.5%) at 1 µL. The absolute error decreases, but the relative error rises, meaning accuracy at the low end of the range is more sensitive to technique. Users should account for this when performing sub-5 µL transfers.

What tip compatibility requirements should be considered for the HiPette 0.5-10 µL pipette?

The pipette requires tips designed for the 0.5-10 µL volume range to ensure proper fit and seal. The product description advises confirming compatible tips before ordering, but does not specify a particular brand or tip type. In practice, standard 10 µL filter tips or universal low-retention tips are typically used, but users should verify compatibility to avoid leakage or inaccuracy.

What sterilization procedure is recommended for the HiPette 0.5-10 µL pipette, and what are the implications for laboratory workflow?

The HiPette 0.5-10 µL pipette is fully autoclavable, allowing sterilization via autoclaving for aseptic applications such as PCR setup. This eliminates the need for chemical disinfectants, but repeated autoclaving may affect calibration over time. Users should follow the manufacturer's disassembly and reassembly instructions and consider recalibration after sterilization cycles.

Fully autoclavable single-channel pipette covering 0.5-10 µL with 0.01 µL increment; systematic and random errors calibrated per ISO 8655-2 at 10, 5, and 1 µL test volumes, with accuracy diminishing at the lower end of the range.

Positive

  • Fully autoclavable without disassembly: The entire pipette can be sterilized by autoclaving, ensuring decontamination between uses without requiring partial disassembly or specialized cleaning protocols.
  • Calibrated per ISO 8655-2 with test volumes: Systematic and random errors are provided for three test volumes (10, 5, 1 µL), enabling traceable calibration verification and method-specific accuracy assessment.

Trade-offs

  • Limited to sub-10 µL volumes only: The working range of 0.5-10 µL restricts the pipette to microliter-scale transfers; larger volumes require a different instrument, increasing lab inventory needs.
  • Accuracy declines at lowest test volumes: At 1 µL, systematic error reaches ±2.5% and random error ±1.8%, which may be inadequate for high-precision applications requiring tighter tolerances at minimal volumes.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).