HiPette 0.1-2.5 μL Single-Channel Pipette ATOMFAIR®

$88.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette single-channel pipette for 0.1-2.5 μL transfer with 0.002 μL increments and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HIPP-A025-SC00
Category:
Tags:
Brands:

Description

HiPette Single-channel 0.1-2.5 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette Single-channel 0.1-2.5 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.1-2.5 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 0.1-2.5 µL working range, 0.002 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 0.1-2.5 µL with 0.002 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-0-1-2-5-µL
Product Family HiPette
Channel count Single-channel
Volume range 0.1-2.5 µL
Increment 0.002 µL
Test volume(s) 2.5 / 1.25 / 0.25 µL
Systematic error At 2.5 µL: ±0.04 µL (±1.4%); at 1.25 µL: ±0.03 µL (±2.5%); at 0.25 µL: ±0.03 µL (±12.0%)
Random error At 2.5 µL: ±0.02 µL (±0.7%); at 1.25 µL: ±0.02 µL (±1.5%); at 0.25 µL: ±0.02 µL (±6.0%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires selection of compatible tips and periodic autoclave sterilization to maintain performance. Calibration must be verified according to ISO 8655-2 using the specified test volumes.

  • Tip Compatibility: Compatible tips must be confirmed for the 0.1-2.5 µL volume range before liquid handling.
  • Sterilization Procedure: Full autoclaving at 121°C is permitted and recommended to prevent cross-contamination.
  • Calibration Verification: Systematic and random errors must be checked at test volumes 2.5, 1.25, and 0.25 µL per ISO 8655-2.

How does the systematic error of the HiPette 0.1-2.5 µL pipette vary across its volume range, and what is the trade-off in accuracy at low volumes?

The systematic error increases from ±1.4% at 2.5 µL to ±12.0% at 0.25 µL, reflecting a trade-off between working at the upper end of the range for better accuracy versus the lower end for smaller volumes. The random error similarly increases from ±0.7% to ±6.0% over the same test volumes, as specified in the technical specifications.

What specific tip compatibility requirements or calibration standards must be met for the HiPette 0.1-2.5 µL pipette to ensure accurate operation in ISO 8655-2 compliant workflows?

The pipette is calibrated to ISO 8655-2 and requires compatible tips for the 0.1-2.5 µL volume range to maintain specified systematic and random error tolerances. Users should confirm tip compatibility with the manufacturer before use, as incorrect tip fit can compromise accuracy and calibration integrity.

What are the sterilization requirements for the HiPette 0.1-2.5 µL pipette, and how does full autoclavability affect routine laboratory handling and maintenance?

The HiPette 0.1-2.5 µL pipette is fully autoclavable, allowing sterilization between uses to prevent cross-contamination. This requires that the pipette be disassembled and reassembled according to manufacturer instructions, and users should verify that repeated autoclavation does not alter calibration accuracy over time.

The HiPette Single-channel 0.1-2.5 µL pipette offers full autoclavability and precise low-volume dispensing with a 0.002 µL increment and traceable error data, but users must account for significantly reduced accuracy near the minimum volume and verify tip compatibility and calibration requirements before ordering.

Positive

  • Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling effective decontamination between uses and supporting aseptic laboratory workflows.
  • Precise low-volume dispensing: With a 0.002 µL increment and ISO 8655-2 traceable systematic and random error values at test volumes, the pipette provides reliable accuracy for microliter-scale liquid handling.

Trade-offs

  • High error at minimum volume: At 0.25 µL, the systematic error reaches ±12.0%, significantly degrading accuracy at the lower end of the working range.
  • Pre-use configuration needed: Compatible tips, calibration requirements, sterilization needs, and laboratory workflow must be confirmed before ordering to ensure proper operation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).