High-Temperature Vacuum Quench Furnace 1400 °C TF-1400-15 ATOMFAIR®

$12,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Vertical vacuum quench furnace with sealed liquid tank, 1400 °C maximum temperature, AC220V 50/60Hz, for metal sample treatment. Order now.

SKU: AF-TF-Q-1400-9RSS-0015
Category:
Tags: , , ,
Brands:

High-Temperature Vacuum Quench Furnace, 1400 °C
LABORATORY THERMAL PROCESSING EQUIPMENT
Product Overview

High-Temperature Vacuum Quench Furnace, 1400 °C is a vacuum/atmosphere tube furnace for controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development.

The configuration focuses on A vertical vacuum quenching furnace with a sealed liquid storage tank.

Additional configuration points include Samples can be quenched in vacuum or atmosphere, from the highest temperature of 1400 degrees into ice water or oil, to a large extent reduce the oxidation and deformation of the sample, suitable for various metal samples quenching.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model TF-1400-15
Product Family vacuum/atmosphere tube furnace
Configuration Focus A vertical vacuum quenching furnace with a sealed liquid storage tank.
Process Fit controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development
Quotation Confirmation Confirm temperature class, tube or chamber size, heating-zone layout, gas/vacuum package, power supply and required accessories.
Configuration Highlights
  • A vertical vacuum quenching furnace with a sealed liquid storage tank.
  • Samples can be quenched in vacuum or atmosphere, from the highest temperature of 1400 degrees into ice water or oil, to a large extent reduce the oxidation and deformation of the sample, suitable for various metal samples quenching.
  • Voltage rated: AC220V 50/60Hz.
  • Working Temperature.
  • Max. Temperature: 1400 °C( 1 hr).
APPLICATION SCOPE: controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging for handling, storage and delivery.
IMPORTANT NOTICE: Please confirm temperature class, usable process size, gas/vacuum package, power supply and accessory configuration before quotation.
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Operate only with compatible quenching media (ice water or oil) to avoid violent reactions or equipment damage. Ensure electrical supply meets rated voltage and includes emergency shutdown provisions.

  • Vacuum Integrity: Maintain vacuum seals and monitor pressure to prevent oxidation or contamination during high-temperature processing.
  • Quenching Media Compatibility: Use only ice water or oil as quenching media; incompatible liquids may cause rapid vaporization or chemical attack on the chamber.
  • Thermal Shock Limits: Avoid rapid temperature changes exceeding the furnace's rated ramp rate to prevent refractory cracking.
  • Electrical Safety: Connect to a dedicated AC220V 50/60Hz circuit with ground fault protection and accessible disconnect.
  • Liquid Storage Tank Containment: Ensure the sealed liquid storage tank is properly vented and secured to prevent spills during quenching.

Follow these steps to initialize the furnace, load samples, perform vacuum or atmosphere quenching, and safely shut down. Always wear appropriate personal protective equipment and verify system integrity before each run.

Required Equipment: Vacuum pump system, Inert gas supply (if atmosphere treatment required), Quenching media container with ice water or oil, Sample handling tongs and crucible

  1. Inspect System
    Inspect all vacuum seals, electrical connections, and quenching media levels before starting.
  2. Load Sample
    Load the sample into the furnace chamber using appropriate handling tools and secure the door.
  3. Evacuate Chamber
    Evacuate the chamber to desired vacuum level or backfill with inert gas as required.
  4. Set Temperature Profile
    Set the heating program with ramp rate and soak time according to the sample's thermal process requirements.
  5. Initiate Heating
    Initiate heating and monitor temperature and pressure continuously until the target temperature is reached.
  6. Perform Quench
    After soak, quickly transfer the sample from the hot zone into the quenching media under vacuum or atmosphere as configured.
  7. Shut Down
    Allow furnace to cool below safe handling temperature before opening chamber and cleaning any residues.

What is the maximum operating temperature and hold time of the Atomfair TF-1400-15 vacuum quench furnace?

The furnace has a maximum temperature of 1400°C, which can be held for 1 hour as stated in the technical specifications. This peak temperature is suitable for annealing, sintering, and other high-temperature thermal processes in a controlled vacuum or atmosphere.

Can the Atomfair TF-1400-15 quench samples in both vacuum and atmosphere environments?

Yes, the furnace supports quenching in both vacuum and atmosphere. Samples can be directly quenched from 1400°C into ice water or oil while under vacuum or flowing gas, significantly reducing oxidation and deformation. This makes it suitable for various metal sample quenching applications.

What power supply is required for the Atomfair TF-1400-15 vacuum quench furnace?

The furnace requires an AC220V power supply at 50/60 Hz, as specified in the configuration highlights. Confirm that the facility's electrical infrastructure matches this voltage and frequency before installation.

The Atomfair TF-1400-15 vertical vacuum quench furnace provides controlled high-temperature processing up to 1400°C with the ability to quench samples in vacuum or atmosphere into ice water or oil, reducing oxidation and deformation. Operation requires AC220V 50/60Hz power and the peak temperature is limited to 1 hour.

Positive

  • Vertical vacuum quench with sealed tank: Enables quenching in vacuum or atmosphere from 1400°C into ice water or oil, significantly reducing oxidation and deformation of metal samples.
  • 1400°C maximum temperature: Achieves 1400°C for 1 hour, suitable for high-temperature thermal processing of various metal samples.

Trade-offs

  • Specific power requirement: Requires AC220V 50/60Hz power supply, which may necessitate electrical infrastructure or transformer for different regional standards.
  • Limited peak temperature duration: Maximum temperature of 1400°C is sustained for only 1 hour, potentially insufficient for longer high-temperature processes.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).