H-Type Photoelectrochemical Cell 30-250mL ATOMFAIR®

Price range: $386.00 through $575.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade H-type photoelectrochemical cell with quartz window >95% transmittance, 30-250 mL capacity, ion-exchange membrane separation. Order now.

Single-Window H-Type Replaceable-Membrane Photoelectrochemical Cell, Relative Sealed, Single-Layer | ATOMFAIR

Product Type: Electrochemical cell
Research-grade laboratory product

Product Overview

The ATOMFAIR® Single-Layer Relative Sealed Single-Window H-Type Replaceable-Membrane Photoelectrochemical Cell features a high-borosilicate glass body with a quartz window offering light transmittance greater than 95%. The quartz window is connected to the cell body via a galvanized plate assembly, ensuring reliable sealing while allowing quick and convenient replacement of the quartz window. The cell is designed for three-electrode systems with volumes ranging from 30mL to 250mL, with custom capacities available upon request. The cathode and anode chambers are isolated by an ion-exchange membrane, with chain-sealed connections facilitating easy membrane replacement. The working electrode and reference electrode are positioned in the same compartment to effectively reduce uncompensated resistance (iR drop). The cell features a 360° rotatable PTFE inner core for precise electrode alignment (typically parallel to the membrane). The single-layer body features an elevated floor design that effectively eliminates solution hiding effects. Extended-length electrodes are required and must be ordered separately.

Performance Features

  • High-transparency quartz window: ≥95% light transmittance for superior photoelectrochemical and spectroscopic measurements.
  • Quick-change window assembly: Galvanized plate connection enables rapid and convenient replacement of the quartz window without compromising seal integrity.
  • Two-compartment membrane separation: Isolates cathode and anode with ion-exchange membrane for selective ion transport studies.
  • Chain-sealed membrane connections: Facilitates quick and convenient membrane replacement without compromising seal integrity.
  • High-borosilicate glass construction: Excellent chemical resistance and thermal stability across a wide range of electrolytes.

Technical Specifications

Parameter Specification / Available Values
Product Family Single-Window H-Type Replaceable-Membrane Photoelectrochemical Cell, Relative Sealed, Single-Layer
Atomfair Model AF-C023-030-SGL
Volume 30 mL
Atomfair Model AF-C023-050-SGL
Volume 50 mL
Atomfair Model AF-C023-100-SGL
Volume 100 mL
Atomfair Model AF-C023-150-SGL
Volume 150 mL
Atomfair Model AF-C023-200-SGL
Volume 200 mL
Atomfair Model AF-C023-250-SGL
Volume 250 mL
APPLICATION SCOPE: Photoelectrochemistry, membrane-based photoelectrochemical studies, CO₂ reduction, nitrogen reduction, fuel cell research, electrosynthesis, and general photoelectrochemical experiments requiring compartment isolation and optical access.
PACKAGING: Individual shock-proof packaging with specialized foam lining and reinforced cartons to ensure the glass body and quartz window remain intact during transportation.
IMPORTANT NOTICE: Ion-exchange membrane not included. Electrodes not included – use extended-length electrodes. Handle quartz window with care to avoid scratches. Ensure proper sealing of window assembly before use. Avoid thermal shock. Verify membrane compatibility with electrolyte before use. Inspect seals before assembly.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This photoelectrochemical cell requires careful handling of its quartz window to prevent scratches and must be sealed properly before use. Membrane compatibility with the electrolyte must be verified, and thermal shock must be avoided to maintain structural integrity.

  • Quartz Window Care: Handle the quartz window with care to avoid scratches that could compromise optical performance.
  • Window Assembly Sealing: Ensure proper sealing of the window assembly before use to prevent electrolyte leakage.
  • Thermal Shock Avoidance: Avoid thermal shock to the borosilicate glass body to prevent cracking.
  • Membrane Compatibility Verification: Verify membrane compatibility with the electrolyte before use to prevent degradation or failure.
  • Seal Inspection: Inspect all seals before assembly to ensure integrity and prevent leaks.

How does the elevated floor design in the ATOMFAIR single-layer H-type cell eliminate solution hiding effects?

The elevated floor design physically raises the working electrode above the bottom of the cell, preventing the electrode from sitting in stagnant solution that can cause optical and electrochemical artifacts. This design effectively eliminates solution hiding effects, ensuring more accurate photoelectrochemical measurements by maintaining uniform light exposure and electrolyte access to the electrode surface.

What type of electrodes are compatible with the ATOMFAIR AF-C023 single-window photoelectrochemical cell?

The cell requires extended-length electrodes, which must be ordered separately. It is designed for a three-electrode system with the working and reference electrodes positioned in the same compartment to reduce uncompensated resistance (iR drop). Standard electrodes are not compatible due to the cell geometry and the 360° rotatable PTFE inner core used for precise alignment.

What critical precautions should be taken when handling and maintaining the quartz window on the Atomfair H-type photoelectrochemical cell?

The quartz window, which provides >95% light transmittance, must be handled with care to avoid scratches. Before use, ensure proper sealing of the window assembly and inspect all seals to prevent leaks. Avoid thermal shock by not exposing the borosilicate glass body or quartz window to rapid temperature changes. If the window is replaced via the galvanized plate assembly, verify the seal integrity after reassembly.

Single-window H-type photoelectrochemical cell with replaceable membrane, quartz window offering ≥95% light transmittance, and chain-sealed membrane connections for convenient replacement. Available in 30–250 mL volumes. Requires extended-length electrodes and ion-exchange membrane (not included).

Positive

  • High-transparency quartz window: Quartz window provides ≥95% light transmittance, enabling superior photoelectrochemical and spectroscopic measurements with minimal optical loss.
  • Chain-sealed membrane connections: Chain-sealed connections allow quick and convenient replacement of the ion-exchange membrane without compromising seal integrity, reducing downtime between experiments.

Trade-offs

  • Extended-length electrodes required: Extended-length electrodes are not included and must be ordered separately, adding to initial setup cost and procurement effort.
  • Quartz window fragility and thermal sensitivity: Quartz window must be handled with care to avoid scratches; thermal shock must be avoided to prevent damage to the glass body and window.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Capacity / Size

30mL, 50mL, 100mL, 150mL, 200mL, 250mL

Related Products