Description
TC2000-G3 Gradient Thermal CyclerProduct Type: Temperature control instrument
Research-grade temperature control platform
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
Operate the instrument within an ambient temperature range of 5 to 40 °C and relative humidity up to 80% to maintain thermal accuracy. Connect to a grounded power supply rated 100–240 V, 50/60 Hz, 1500 W; the heated lid can reach 115 °C and presents a burn hazard during operation.
- Environmental Limits: Maintain ambient conditions between 5–40 °C and ≤80% RH to avoid condensation and ensure temperature uniformity.
- Electrical Safety: Use a dedicated, grounded outlet matching the instrument's 1500 W power draw to prevent overload.
- Thermal Hazard: The heated lid operates up to 115 °C; allow lid to cool before contact after a run.
- Sample Compatibility: Only use compatible 0.2 mL PCR tubes, 8-strip tubes, or 96-well PCR plates as specified for the block.
Power on the instrument and configure the temperature program via the touch screen interface. Load samples into the appropriate block format, close the heated lid, and start the run while monitoring for errors.
Required Equipment:
- Power On
Connect the power cord to a grounded outlet and switch on the main power. - Program
Set the desired temperature program parameters including temperature, time, and gradient using the touch screen. - Load Samples
Load the sample vessels into the block and confirm proper seating. - Close Lid
Close the heated lid and verify the lid temperature setting. - Start Run
Initiate the run and monitor progress via the display. - End Run
When the run completes, allow the lid to cool before opening to retrieve samples.
How does the TC2000-G3 maintain its specified temperature accuracy of ±0.1°C across the programmable gradient range of 1–25°C, especially at the maximum ramp rate of 5°C/sec?
The TC2000-G3 achieves a temperature accuracy of ±0.1°C and a display resolution of 0.1°C across its entire gradient range (1 to 25°C). Even at the maximum ramp rate of 5°C/sec, the instrument's block/tube control mode and uniform heating design (temperature uniformity ±0.2°C at 55°C) ensure precise thermal performance without compromising accuracy, as specified in the technical datasheet.
What are the power and environmental requirements for installing the TC2000-G3 in a standard laboratory, and does it support 0.2 mL 96-well PCR plates directly?
The TC2000-G3 directly supports 0.2 mL 96-well PCR plates, 96 x 0.2 mL PCR tubes, and 12 x 0.2 mL PCR 8-strip tubes. It requires a power supply of 100–240 V, 50/60 Hz, and consumes up to 1500 W. The operating environment must be 5 to 40°C with ≤80% relative humidity. The instrument dimensions are 310 x 422 x 264 mm and weighs 11 kg, making it suitable for standard benchtop installation.
Does the TC2000-G3 offer any data protection features for long-term unattended thermal cycling protocols, and what is the maximum program storage capacity?
The TC2000-G3 includes power-off protection to safeguard protocols during unexpected power loss. It can store over 20,000 programs and supports user-defined programs of up to 30 steps, with up to 199 cycles. Programs can also be backed up via USB flash drive. The instrument uses USB and WiFi for data transfer and remote monitoring.
The TC2000-G3 Gradient Thermal Cycler offers precise dry-block temperature control with ±0.1°C accuracy and a wide 0-105°C range, suitable for molecular biology workflows. However, its 1500W power draw and lack of shaking capability impose infrastructure and application constraints.
Positive
- High temperature accuracy and uniformity: Temperature accuracy of ±0.1°C and uniformity of ±0.2°C at 55°C ensure reproducible incubation conditions for sensitive enzymatic reactions and nucleic acid workflows.
- Broad temperature range with gradient capability: Sample module range from 0 to 105°C with a gradient span of 1 to 25°C enables optimization of annealing temperatures and supports diverse thermal protocols.
Trade-offs
- High power consumption: Rated at 1500 W, the instrument requires a dedicated electrical circuit and may not be compatible with standard lab bench power outlets in all facilities.
- No integrated shaking module: The unit lacks orbital or vortex mixing capability, limiting its use to static incubation only; applications requiring agitation must use external shakers.