$410.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

HB150-S2 dry bath offers RT+5 to 150°C control, ±0.3°C accuracy to 90°C, ±0.2°C uniformity at 37°C and 200 W power. Order now.

Description

ATOMFAIR® HB150-S2 Dry Bath

Product Type: Temperature control instrument
Atomfair Model: AF-TC-HB150-S2
Research-grade temperature control platform

Product Overview

ATOMFAIR® HB150-S2 Dry Bath is a research-grade dry bath that provides controlled heating, cooling, incubation, shaking or nucleic-acid amplification for temperature-sensitive laboratory workflows. It is intended for laboratories that need dependable daily operation, clear configuration options and product data that can be reviewed before procurement or method deployment.

Typical applications include PCR setup, qPCR analysis, enzyme reactions, sample preservation, tube incubation, plate preparation, protein work, cell biology support and routine quality-control testing. The product description is written for scientific users and procurement teams who need to understand how the item fits into experimental preparation, routine analysis, process support, quality-control workflows or teaching laboratory use. Selection should consider sample format, temperature range, uniformity, ramp performance, module compatibility, program capacity, lid or block configuration and cleaning requirements. Key source parameters include Temperature setting range: 25 to 150 C; Temperature control accuracy: 25 to 90 C: +/-0.3 C; 90 to 150 C: +/-0.6 C; Uniformity at 37 C: +/-0.2 C; Power: 200 W, with the full specification table retained below for detailed technical review. The tables below preserve model-specific specifications, capacities, dimensions, operating limits and compatible components so users can evaluate the product with the level of detail expected for professional scientific procurement.

Key Features and Advantages

  • Research-grade configuration for professional laboratory, R&D and quality-control workflows.
  • Application scope covers PCR setup, qPCR analysis, enzyme reactions, sample preservation, tube incubation, plate preparation, protein work, cell biology support and routine quality-control testing.
  • Structured specification tables retain the operating range, capacity, dimensions, compatibility and performance data required for technical review.
  • Selection should consider sample format, temperature range, uniformity, ramp performance, module compatibility, program capacity, lid or block configuration and cleaning requirements.

Technical Specifications

Parameter Specification / Available Values
Temperature control range Room temperature +5 to 150 C
Temperature setting range 25 to 150 C
Temperature control accuracy 25 to 90 C: +/-0.3 C; 90 to 150 C: +/-0.6 C
Uniformity at 37 C +/-0.2 C
Power 200 W
Timer 0 min to 99 h 59 min
Display LED
Power supply 110/220 V, 50/60 Hz
Dimensions 290 x 210 x 120 mm
Weight 3.2 kg
Ambient temperature 10 to 40 C
Relative humidity <80%

Atomfair Product Ordering and Comparison Table

Unique Atomfair Order Model Product Name Differentiating Specification Value
AF-TC-HB150-S2 Bath Room temperature +5 to 150 C Dry Bath
Data Handling Standard: Product information is presented in English-only HTML with specifications retained in structured tables for quotation, comparison and configuration matching.
Ordering Standard: Confirm model, capacity, accessory compatibility and operating requirements before ordering.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The instrument requires an ambient temperature of 10 to 40 °C and relative humidity below 80% for stable operation. Temperature control accuracy degrades above 90 °C, with a specified tolerance of ±0.6 °C from 90 to 150 °C.

  • Ambient Operating Range: Operate the dry bath only within an ambient temperature range of 10 to 40 °C and relative humidity below 80% to maintain specified performance.
  • Temperature Accuracy Degradation at High Setpoints: When setting the block temperature above 90 °C, expect control accuracy to widen to ±0.6 °C compared to ±0.3 °C in the 25 to 90 °C range.

This procedure covers initial setup, block installation, and routine operation for temperature-sensitive workflows. Follow each step sequentially to ensure safe and accurate thermal control.

Required Equipment: ATOMFAIR HB150-S2 Dry Bath unit, Compatible sample block or module

  1. Place the instrument on a stable, level surface
    Position the dry bath on a clean, level benchtop away from direct sunlight and drafts to ensure uniform heat distribution.
  2. Install the appropriate sample block
    Insert the compatible block or module into the heating well, ensuring full contact with the base for optimal thermal transfer.
  3. Connect the power supply and turn on the unit
    Plug the power cord into a grounded outlet matching the specified voltage (110/220 V, 50/60 Hz) and switch on the main power.
  4. Set the target temperature and timer
    Use the LED interface to enter the desired temperature between 25 and 150 °C and set the timer from 0 minutes up to 99 hours 59 minutes.
  5. Load samples into the preheated block
    Once the display indicates the setpoint has been reached, carefully place tubes or plates into the block wells without overfilling.
  6. Monitor the run and retrieve samples upon completion
    Allow the timer to elapse or stop the run manually, then remove samples using heat-resistant gloves if the block temperature exceeds 60 °C.

What is the temperature control accuracy trade-off between the lower and upper operating ranges of the Atomfair HB150-S2 dry bath?

The accuracy is ±0.3°C from 25°C to 90°C, but degrades to ±0.6°C from 90°C to 150°C per the technical specifications. Applications requiring tight thermal control above 90°C must account for this reduced precision.

Can the Atomfair HB150-S2 dry bath perform active cooling below ambient temperature?

No, the temperature control range is room temperature +5°C to 150°C with a setting range of 25°C to 150°C. It cannot cool below ambient; only heating above room temperature is supported, which is a constraint for protocols requiring rapid cooling or sub-ambient incubation.

What are the ambient operating limits for the Atomfair HB150-S2 dry bath and how do they affect laboratory placement?

The instrument must be operated in ambient temperatures of 10°C to 40°C and relative humidity below 80%. It requires a 110/220V, 50/60Hz power supply and consumes 200W. Placement should avoid high-humidity areas and ensure adequate ventilation for heat dissipation.

The Atomfair HB150-S2 Dry Bath offers precise temperature uniformity at 37°C and a wide heating range, but users must account for reduced accuracy above 90°C and controlled ambient requirements.

Positive

  • Precise temperature uniformity at 37°C: Uniformity of ±0.2°C at 37°C supports reproducible enzyme reactions and PCR setup.
  • Broad operational temperature range: Range from room temperature +5 to 150°C covers incubation, denaturation, and nucleic-acid amplification protocols.

Trade-offs

  • Reduced accuracy above 90°C: Temperature control accuracy degrades to ±0.6°C in the 90–150°C range, which may limit high-temperature applications requiring tighter tolerance.
  • Restricted ambient operating conditions: Ambient temperature must be between 10 and 40°C with relative humidity below 80%, limiting use in unconditioned laboratory spaces.