Description
dPette+ Single-channel 30-300 µL PipetteProduct Type: Electronic pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires routine calibration per ISO 8655-2 and has sterilization limitations due to autoclavable lower half only. Tip compatibility must be confirmed for optimal performance and accuracy.
- Calibration Reference: Systematic and random error tolerances are specified at three test volumes to validate performance.
- Sterilization Limitation: Only the lower half is autoclavable; the upper assembly must not be exposed to steam sterilization.
- Tip Selection Requirement: Compatible tips must be selected to maintain specified accuracy and repeatability.
What is the systematic error tolerance of the dPette+ 30-300 µL pipette at the lowest test volume compared to the highest, and how does this affect its suitability for low-volume applications?
At 300 µL the systematic error is ±0.60%, while at 30 µL it is ±4.00%. This ten-fold increase in relative error at the low end means the pipette is less accurate for volumes near its minimum and better suited for mid-to-high range transfers where error is under 1%.
Is the dPette+ 30-300 µL pipette fully autoclavable, and what parts of the instrument can be sterilized for aseptic laboratory workflows?
Only the lower half of the pipette is autoclavable; the upper electronic assembly is not. The product explicitly states 'Lower half autoclavable.' For full sterilization, users should disassemble and autoclave only the tip-holding lower portion.
What calibration standard does the dPette+ pipette adhere to, and can users perform on-site calibration verification without sending the instrument to a service center?
The pipette's calibration reference is ISO 8655-2, and a user calibration procedure is indicated in the technical table. This supports on-site verification by trained personnel using the specified test volumes and acceptable error ranges, but full recalibration may require certified equipment.
The dPette+ Single-channel 30-300 µL pipette is a manual liquid handling platform with a fully autoclavable lower half and ISO 8655-2 calibration traceability. Its accuracy degrades at the low end of the range (30 µL: ±4.00% systematic error), and sterilization is limited to the lower half only.
Positive
- Autoclavable lower half: The lower half of the pipette can be sterilized by autoclaving, reducing contamination risk in microbiological and PCR workflows.
- ISO 8655-2 calibration traceability: Systematic and random error values are provided per ISO 8655-2 at three test volumes, enabling traceable calibration and performance verification.
Trade-offs
- Partial sterilization coverage: Only the lower half is autoclavable; the upper assembly cannot be sterilized by autoclaving, limiting complete decontamination options.
- Reduced accuracy at low volume: At 30 µL, the systematic error is ±4.00%, significantly higher than at 300 µL (±0.60%), which may affect low-volume precision.