Engineered for high-capacity backup infrastructure deployments, this industrial condensed core battery system delivers ultra-reliable power reserves for critical data center emergency power UPS installations. Utilizing a high-density, low-impedance chemical core layout, the 51.2V 100Ah 5.12kWh backup platform comfortably achieves ≥95% round-trip conversion efficiency. This structural design easily sustains an intensive IP68 rated high rate 6C discharge profile to bridge sudden infrastructure grid loss windows without voltage sag. Built into a standardized 4U rack-mount chassis configuration, it features superior immunity to strong electromagnetic interference (EMI) alongside extreme fire isolation metrics. It serves as an essential primary power safeguard for corporate cloud server arrays, heavy communications switching nodes, and automated stationary energy backup facilities. For bulk inquiries or official volume quotations, please contact us via email at inquiry@atomfair.com.

Technical Specifications

PARAMETER VALUE
Nominal Voltage / Rated Capacity 51.2 V / 100 Ah
Rated Energy Output 5.12 kWh
Charge Cut-off Voltage 58.4 V
Discharge Voltage Range 40 V – 58.4 V
Standard / Maximum Charge Rate 0.3C – 1C (Standard Window) | 1C Maximum Continuous
Continuous Discharge Rate Window 1C – 6C Dynamic Discharge Flow
Charge/Discharge Efficiency ≥95% (Evaluated @ 1C, 25 °C Ambient)
Operating Temperature Windows Discharging: -20 °C ~ 60 °C | Charging: 0 °C ~ 40 °C (Recommended: 15 °C ~ 35 °C)
Physical Chassis Form Factor 482.6 × 600 × 177.8 mm (Standard 4U Rack Integration Geometry)
Total Operational System Weight Approx. 45 – 50 kg (Including Casing, BMS Framework, and Cable Arrays)
Protection & Flame Retardant Ratings IP68 Enclosure Isolation Grade | UL94 V-0 Highest Fire Proofing Rating
Compliance Testing Standards UL 1642, UL 1973, IEC 62619, UN 38.3 Shipping Certified
Environmental Adaptability Profiles Vibration Resistant, Salt Fog Shielded, Acid/Alkali Shielded; Rigid Stability Under High-Voltage EMI Blocks
Alternative Catalog Items Explore our complete component catalog for alternative volumetric capacities, high-conductivity polymer separators, aluminum-laminated protective packaging films, or multi-channel battery cycling systems.

Key Features & Advantages

  • Condensed Core Technology: Innovative condensed core design delivers ultra-low internal resistance, high thermal stability, and enhanced safety for critical backup power applications.
  • High Power Discharge Capability: Supports flexible discharge rates from 1C to 6C, meeting the surge demands of data center UPS and emergency systems.
  • High Efficiency & Reliability: Achieves ≥95% round-trip efficiency at 1C, reducing energy waste and operating costs.
  • Wide Temperature & Environmental Tolerance: Discharge from -20°C ~ 60°C, IP68 protection, vibration/salt fog/acid-alkali resistance, and stable under EMI/high voltage.
  • Comprehensive Safety Certifications: Compliant with UL 1642/1973, IEC 62619, UN 38.3, and UL94 V-0 flame retardant.

APPLICATION SCOPE: Optimized for centralized data center server server environments, cloud computer farms, critical emergency telecom backups, industrial automated infrastructure, and micro-grid sub-station testing networks.
SHIPPING & LOGISTICS: Dispatched inside heavy-duty, certified industrial protective freight frameworks to handle high weight metrics smoothly. Arrives pre-tested and complete with individual technical logging maps and standard connection bolts.
IMPORTANT NOTICE: This condensed core battery system is designed for data center emergency power and stationary backup. Charge within specified temperature range (0°C ~ 40°C). Do not exceed max charge/discharge rates. Ensure proper ventilation and follow local electrical codes. For best cycle life, operate within recommended temperature range (15°C ~ 35°C during charge). IP68 rating applies to the enclosed system under specified conditions.

TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER: ATOMFAIR LLC
BRAND: ATOMFAIR®

This battery system must be operated within its charge temperature window (0°C to 40°C) and discharge temperature window (-20°C to 60°C) to maintain safety and performance. The unit's IP68 and UL94 V-0 ratings require proper enclosure sealing and protection from physical damage to remain effective.

  • Charge Temperature Constraint: The battery must be charged only when the ambient temperature is between 0°C and 40°C to prevent thermal damage.
  • Discharge Temperature Constraint: Discharge operation is permitted from -20°C to 60°C, but extended exposure outside the recommended range of 15°C to 35°C may reduce cycle life.
  • Rate Limits: Continuous charge current must not exceed 1C and continuous discharge current must not exceed 6C to avoid overheating.
  • Environmental Protection: The IP68 rating is maintained only when all enclosure seals are intact and the system is not subjected to mechanical stress or corrosive environments beyond specified conditions.
  • Compliance Requirements: Installation must comply with local electrical codes and the system must be connected to a properly rated UPS or backup circuit.

Follow these safety steps to ensure the battery system is operated within its design limits during initial deployment. Each step corresponds to a critical operating constraint from the product notice.

  1. Verify Charge Temperature
    Confirm the ambient temperature is between 0°C and 40°C before initiating any charge cycle.
  2. Limit Charge and Discharge Rates
    Limit the charge current to 1C or less and the discharge current to 6C or less during all operation.
  3. Ensure Adequate Ventilation
    Ensure the installation area has adequate ventilation to dissipate heat, especially during high-rate discharge cycles.
  4. Comply with Electrical Codes
    Follow all local electrical codes and regulations when connecting the battery to the UPS system.

What is the maximum continuous discharge current and does the battery maintain voltage stability under 6C dynamic discharge?

The battery supports continuous discharge from 1C to 6C dynamic flow, with 6C corresponding to 600A for the 100Ah capacity. The design sustains an intensive high-rate 6C discharge profile without voltage sag, as stated in the product overview, ensuring stable voltage output during sudden grid loss events.

What environmental and safety certifications qualify this battery for data center emergency power, and how does the IP68 rating apply to the rack-mounted system?

The battery is certified to UL 1642, UL 1973, IEC 62619, and UN 38.3, with a UL94 V-0 flame retardant rating. The IP68 enclosure isolation grade applies to the entire enclosed system under specified conditions, providing protection against dust and immersion, though the important notice states this rating is valid under specified conditions.

What are the recommended charging temperature windows to maximize cycle life, and what happens if the battery is charged below 0°C?

The recommended charging temperature range is 15°C to 35°C, with an allowed range of 0°C to 40°C. Charging below 0°C is not permitted per the important notice, and doing so could damage the battery or reduce cycle life. The specified operating window for discharge is -20°C to 60°C, but charging must be within 0°C to 40°C.

The Atomfair condensed core battery system is a 51.2V 100Ah 5.12kWh rack-mount UPS battery with IP68 protection, UL94 V-0 flame retardancy, and 6C discharge capability, achieving ≥95% round-trip efficiency for data center emergency power.

Positive

  • High-power 6C discharge capability: Supports continuous discharge rates from 1C to 6C, enabling rapid power delivery during grid loss without voltage sag, critical for UPS load surges.
  • Broad environmental and safety certifications: IP68 enclosure, UL94 V-0 flame retardancy, and compliance with UL 1642/1973, IEC 62619, and UN 38.3 ensure reliable operation under vibration, salt fog, and EMI stress.

Trade-offs

  • Narrow charging temperature window: Charging is restricted to 0°C–40°C; optimal cycle life requires 15°C–35°C, limiting deployment in unconditioned environments below freezing or above 40°C.
  • High system weight for rack integration: At 45–50 kg in a 4U chassis, the unit requires reinforced rack rails and careful handling, increasing installation labor and structural load.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Related Products