Vertical Single-Zone Tube Furnace 1200°C TF-1200-10 ATOMFAIR®

$6,700.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

TF-1200-10 vertical tube furnace reaches 1200°C for vacuum or flowing-gas annealing, sintering, film growth and electrode testing at AC208-240V. Order now.

SKU: AF-TF-V-1200-H7J0-0010
Category:
Tags: , , ,
Brands:

Single-Zone Vertical Tube Furnace, 1200 °C
LABORATORY THERMAL PROCESSING EQUIPMENT
Product Overview

Single-Zone Vertical Tube Furnace, 1200 °C is a vertical tube furnace for controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development.

The configuration focuses on Atmosphere injector design inside tube can directly inject the necessary atmosphere onto materials to help react more fully.

Additional configuration points include Sample put horizontally on the inner tube can let gas flow into outer/inner tube simultaneously, and horizontal sample is helpful for film growth& electrode test, with evener temperature.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model TF-1200-10
Product Family vertical tube furnace
Configuration Focus Atmosphere injector design inside tube can directly inject the necessary atmosphere onto materials to help react more fully.
Process Fit controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development
Quotation Confirmation Confirm temperature class, tube or chamber size, heating-zone layout, gas/vacuum package, power supply and required accessories.
Configuration Highlights
  • Atmosphere injector design inside tube can directly inject the necessary atmosphere onto materials to help react more fully.
  • Sample put horizontally on the inner tube can let gas flow into outer/inner tube simultaneously, and horizontal sample is helpful for film growth& electrode test, with evener temperature.
  • The device can also make oxide crystals grow, and anneal, etc.
  • Voltage rated: AC208-240V 50/60Hz.
  • :AC208-240V 50/60Hz.
APPLICATION SCOPE: controlled heating, vacuum or flowing-gas treatment, annealing, sintering and laboratory thermal-process development.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging for handling, storage and delivery.
IMPORTANT NOTICE: Please confirm temperature class, usable process size, gas/vacuum package, power supply and accessory configuration before quotation.
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This furnace requires confirmation of temperature class, tube size, heating-zone layout, gas/vacuum package, and power supply before use. Operation involves high temperatures and electrical hazards, demanding proper containment and safety protocols.

  • Electrical Safety Constraint: Confirm the AC208-240V 50/60Hz power supply matches the facility's electrical infrastructure before energizing the furnace.
  • Atmosphere Injection Constraint: The atmosphere injector design requires proper gas flow management to ensure reactive gases contact materials directly and react fully.
  • Sample Positioning Constraint: Place samples horizontally on the inner tube to allow simultaneous gas flow into outer and inner tubes for even temperature distribution.
  • Process Compatibility Constraint: Verify the furnace's temperature class and heating-zone layout are suitable for the intended annealing, sintering, or thermal-process development.

This procedure covers the safe setup and operation of the furnace for controlled heating, vacuum, or flowing-gas treatments. Follow these steps to ensure proper atmosphere injection and sample positioning.

Required Equipment: Atomfair TF-1200-10 vertical tube furnace, Gas supply or vacuum system, Sample holder or boat

  1. Verify power supply
    Confirm the furnace is connected to an AC208-240V 50/60Hz power source that matches the facility's electrical infrastructure.
  2. Position sample horizontally
    Place the sample horizontally on the inner tube to allow gas flow into both outer and inner tubes simultaneously.
  3. Connect gas or vacuum system
    Attach the gas supply or vacuum system to the furnace's atmosphere injector port, ensuring a secure and leak-free connection.
  4. Set process parameters
    Program the furnace controller with the desired temperature profile, heating rate, and dwell time for the specific thermal process.
  5. Initiate atmosphere flow
    Start the gas flow or vacuum pump to establish the required atmosphere before heating begins.
  6. Start heating cycle
    Begin the heating cycle and monitor the furnace temperature and atmosphere flow throughout the process.
  7. Cool and retrieve sample
    Allow the furnace to cool to a safe temperature before removing the sample, then shut off gas or vacuum systems.

How does the atmosphere injector and horizontal sample placement in the Atomfair TF-1200-10 vertical tube furnace improve gas distribution and temperature uniformity for thin-film growth?

The integrated atmosphere injector directly delivers process gas onto the material, promoting more complete reactions. Additionally, the horizontal sample orientation on the inner tube allows simultaneous gas flow through both outer and inner tubes, which the manufacturer states is helpful for film growth and electrode testing by providing a more even temperature profile.

What are the key specifications to confirm before ordering the TF-1200-10 vertical tube furnace for a specific thermal process?

Before ordering, the buyer must confirm the required temperature class, usable process size (tube or chamber dimensions), heating-zone layout, gas/vacuum package, power supply (rated AC208-240V 50/60Hz), and required accessories. This ensures the furnace configuration matches the intended application, such as controlled heating, annealing, sintering, or vacuum treatment.

What packaging and delivery preparations are included for the Atomfair TF-1200-10 vertical tube furnace?

The furnace is prepared with protective inner materials and reinforced outer packaging designed for safe handling, storage, and delivery. No additional special handling requirements are specified, but the manufacturer recommends confirming all configuration details prior to shipment to avoid compatibility issues upon arrival.

The Atomfair TF-1200-10 single-zone vertical tube furnace features an atmosphere injector that delivers process gas directly onto the sample for enhanced reaction efficiency, and a horizontal sample placement that enables simultaneous gas flow through inner and outer tubes, improving temperature uniformity for film growth and electrode testing.

Positive

  • Atmosphere injector design: Direct injection of process gas onto the sample enhances reaction completeness compared to passive gas flow, critical for controlled atmosphere annealing and sintering.
  • Horizontal sample with dual gas flow: Sample placed horizontally on the inner tube allows simultaneous gas flow into both outer and inner tubes, promoting more uniform temperature distribution and improved film growth and electrode test reproducibility.

Trade-offs

  • Pre-order configuration required: Temperature class, tube size, gas/vacuum package, and power supply must be confirmed before quotation, adding procurement complexity and lead time for non-standard configurations.
  • Specific power supply range: Rated for AC208-240V 50/60Hz, requiring dedicated electrical infrastructure or step-down transformer in facilities with standard 120V outlets, potentially limiting drop-in deployment.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).