AGV Robot Battery System 41.6V 233.1Ah 9.7kWh ATOMFAIR®

$2,850.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Commercial-grade AGV robot battery system with 41.6V, 233.1Ah and 9.7kWh capacity, 466A peak discharge, 395×245×574 mm rugged chassis. Order now.

Brands:

41.6V 233.1Ah ROBOT BATTERY SYSTEM | ATOMFAIR

COMMERCIAL GRADE · PRODUCTION

Product Overview

High-throughput automated logistics lines demand rigorous, optimized frameworks, and this premium AGV robot battery system delivers ultra-low internal resistance profiles via integrated condensed core power supply hardware engineering. Tailored to operate as a heavy-duty 41.6V 233.1Ah industrial battery cornerstone, this system supplies a robust high rate 9.7kWh robotic pack energy baseline designed for twenty-four seven continuous execution cycles. It supports a massive 116A rated charge current coupled with a 466A peak current discharge threshold to manage rapid turnaround docking sequences comfortably. Encased inside a tight 50 kg mechanical chassis built to withstand harsh facility vibration sweeps, this package ensures high thermal safety limits across wide processing zones. It serves as an essential primary energy assembly for automated guided vehicles, intelligent super charging stations, and industrial robotic arms. For bulk inquiries or official volume quotations, please contact us via email at inquiry@atomfair.com.

Technical Specifications

PARAMETER VALUE
Nominal Voltage Potential 41.6 V DC Centerline Potential
Operational Voltage Window 32.5 V DC – 47.45 V DC Cut-off Limits
Nominal Capacity Threshold 233.1 Ah (Evaluated @ 0.5P Rate, 25°C Ambient Environment)
Nominal Energy Rating 9.7 kWh Cumulative Capacity Baseline
Rated Charge / Peak Charge Current 116 A Continuous Rated / 233 A Peak Max Window (1C Rate Limit)
Rated Discharge / Peak Discharge Current 233 A Continuous Rated (1C) / 466 A Peak Max Burst (2C Rate Limit)
Charge / Discharge Operational Temperature Charging Window: 0°C to 50°C | Discharging Window: -20°C to 50°C
Storage Conditions Limits Temperature Range: -30°C to 60°C | Relative Humidity Scope: Unlimited Protection
Maximum Operating Altitude ≤ 2000 meters Structural Centerline Cap
Chassis Physical Enclosure Size 395 mm × 245 mm × 574 mm (W × H × D) Frame Footprint
Total Equipment Mass 50 ± 5 kg Rugged Heavy Assembly Mass
Alternative Catalog Items Explore our complete component catalog for alternative volumetric capacities, high-conductivity polymer separators, aluminum-laminated protective packaging films, or multi-channel battery cycling systems.

Key Features & Advantages

  • Condensed Core Technology: High-efficiency core design delivers ultra-low internal resistance and excellent thermal stability, enabling high-rate charge/discharge for AGV super charging robots.
  • High Power Charge & Discharge: Rated charge 116A / peak 233A (1C), rated discharge 233A (1C) / peak 466A (2C), ensuring rapid turnaround for automated guided vehicles.
  • Wide Temperature Operation: Charge from 0°C to 50°C, discharge from -20°C to 50°C, storage from -30°C to 60°C, reliable in diverse warehouse and outdoor environments.
  • Robust Energy Capacity: 9.7kWh energy in a compact 395×245×574 mm package, weighing ~50kg — optimized for AGV integration.
  • Extreme Environmental Adaptability: Unlimited humidity, ≤2000m altitude operation, designed for 24/7 industrial use.

APPLICATION SCOPE: Highly recommended for commercial automated guided vehicles (AGV fleets), industrial material handling systems, high-rate robotic charging docks, and smart factory floor automated machinery.
SHIPPING & LOGISTICS: Securely crated inside heavy, shock-insulated transport packaging built to meet international freight handling guidelines. Each module bundle arrives individual-tested and complete with official parameter calibration data sheets.
IMPORTANT NOTICE: This condensed core battery is designed for AGV super charging robot applications. Ensure charge/discharge within specified temperature ranges. Do not exceed peak current ratings. For peak performance, maintain proper ventilation and follow manufacturer guidelines. Store within -30°C to 60°C when not in use.

TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This battery system requires strict adherence to environmental and electrical limits to ensure safe operation and longevity. Exceeding specified temperature, current, or altitude thresholds may cause thermal runaway or permanent damage.

  • Storage Temperature Range: Store the battery between -30°C and 60°C to prevent irreversible capacity loss.
  • Charge Temperature Range: Charge only when the battery temperature is between 0°C and 50°C to avoid lithium plating.
  • Discharge Temperature Range: Discharge only when the battery temperature is between -20°C and 50°C to maintain performance.
  • Current Limits: Do not exceed a continuous charge current of 116A or a peak discharge current of 466A to prevent overheating.
  • Altitude Limit: Operate the battery at altitudes no greater than 2000 meters to ensure proper cooling and safety.

Follow these steps to safely handle and initialize the battery system for first use. Improper handling may lead to electrical hazard or reduced battery life.

Required Equipment: AGV super charging station

  1. Verify environmental conditions
    Confirm the battery temperature is within the charge temperature range of 0°C to 50°C before connecting the charger.
  2. Set charge parameters
    Program the charger to deliver a continuous charge current not exceeding 116A and a peak current not exceeding 233A.
  3. Ensure proper ventilation
    Maintain adequate ventilation around the battery during charging to dissipate heat.
  4. Check altitude
    Verify that the operating altitude is at or below 2000 meters to ensure safe operation.

Can the 466A peak discharge current be sustained for prolonged operations, or is it limited to burst conditions?

The 466A peak discharge current is rated as a burst maximum at 2C rate limit (Peak Max Burst), not for continuous use. The continuous rated discharge current is 233A (1C). Sustained operation at 466A beyond brief bursts may exceed thermal and safety limits; for continuous high-rate demands, the 233A rated discharge should be used.

Is this 41.6V battery system compatible with standard 48V industrial AGV charging stations?

The battery's operational voltage window is 32.5 V to 47.45 V DC. A standard 48V charging station may exceed the 47.45V maximum during charging, risking overvoltage damage. The charger must deliver the rated charge current (116A continuous / 233A peak) within the battery's voltage limits. Always verify compatibility with the manufacturer's specifications.

What are the temperature and humidity limits for storing this AGV battery when not in use?

The battery can be stored at temperatures from -30°C to 60°C with unlimited relative humidity protection, as stated in the storage conditions. It is designed for extreme environmental adaptability, making it suitable for diverse warehouse and outdoor environments. For best performance, store within the specified range and avoid prolonged exposure to the upper or lower limits.

This 41.6V 233.1Ah AGV battery system leverages condensed core technology for ultra-low internal resistance and high-rate charge/discharge capability (466A peak discharge), enabling rapid turnaround in automated logistics. However, the 50 kg mass and 395×245×574 mm footprint require robust mounting, and charging is restricted to 0°C–50°C, limiting cold-environment operation.

Positive

  • Condensed Core Low Resistance: Ultra-low internal resistance and excellent thermal stability enable high-rate charge/discharge, essential for AGV super charging robots in continuous 24/7 cycles.
  • High Power Charge/Discharge: Rated charge 116A (peak 233A) and rated discharge 233A (peak 466A) support rapid turnaround docking sequences, maintaining throughput in high-density logistics.

Trade-offs

  • Charging Temperature Restriction: Charging is only permitted between 0°C and 50°C; sub-zero charging is not allowed, which may limit deployment in cold warehouses or outdoor environments without pre-conditioning.
  • Heavy Physical Package: At 50 ± 5 kg and dimensions of 395×245×574 mm, the battery requires robust mechanical integration and handling equipment, increasing overall system weight and mounting complexity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Related Products